Rear View; Side View; Drain Connection - Whirlpool JENN-AIR Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Place the free end of the tubing into a container or sink, and
turn on main water supply and flush out tubing until water is
clear. Turn off shutoff valve on the water pipe.
NOTE: Always drain the water line before making the final
connection to the inlet of the water valve to avoid possible
water valve malfunction.
5. Bend the copper tubing to meet the water line inlet which is
located on the back of the ice maker cabinet as shown. Leave
a coil of copper tubing to allow the ice maker to be pulled out
of the cabinet or away from the wall for service.

REAR VIEW

A. Water supply tube clamp
B. Vent hose (drain pump models only)
C. Inlet water tube clamp and supply
line connector
D. Drain hose (drain pump models only)
6. Remove and discard the short, black plastic tube from the end
of the water line inlet.
7. Thread the nut onto the end of the tubing. Tighten the nut by
hand. Then tighten it with a wrench two more turns. Do not
overtighten.
NOTE: To avoid rattling, be sure the copper tubing does not
touch the cabinet's side wall or other parts inside the cabinet.
A
B
C
A. Line to ice maker
B. Nut (purchased)
8. Install the water supply tube clamp around the water supply
line to reduce strain on the coupling.
9. Turn shutoff valve ON.
10. Check for leaks. Tighten any connections (including
connections at the valve) or nuts that leak.
6
A
B
C
D
D
C. Ferrule (purchased)
D. Supplied line from ice maker

Drain Connection

Gravity Drain System
Connect the ice maker drain to your drain in accordance with all
state and local codes and ordinances. If the ice maker is provided
with a gravity drain system, follow these guidelines when installing
drain lines. This will help keep water from flowing back into the ice
maker storage bin and potentially flowing onto the floor, causing
water damage.
Drain lines must have a minimum of ⁵⁄₈" (15.88 mm) inside
diameter.
Drain lines must have a 1" drop per 48" (2.54 cm drop per
122 cm) of run or ¹⁄₄" drop per 12" (6.35 mm per 30.48 cm) of
run and must not have low points where water can settle.
The floor drains must be large enough to accommodate
drainage from all drains.
The ideal installation has a standpipe with a 1¹⁄₂" (3.81 cm) to
2" (5.08 cm) PVC drain reducer installed directly below the
outlet of the drain tube as shown. You must maintain a
1" (2.54 cm) air gap between the drain hose and the
standpipe.
IMPORTANT: A drain pump is necessary when a floor drain is not
available. A Drain Pump kit, Part Number 1901, is available for
purchase.

SIDE VIEW

1⁷⁄₈"
(4.8 cm)
23"
(58.4 cm)
(5 cm - 3.8 cm)
A. Drain hose
B. 1" (2.54 cm) air gap
C. PVC drain reducer
D. Center of drain should be 23" (58.4 cm) from front of door,
with or without the ³⁄₄" (1.91 cm) panel on the door. The
drain should also be centered from left to right (7 ⁵⁄₁₆ "
[18.56 cm] from either side of the ice maker).
A
B
1" (2.54 cm)
C
D
2" - 1¹⁄₂"

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido