A2006
Speed
reference
error
A2009
Over tem-
perature
A5001
Internal
error
F0001
Over cur-
rent
F0002
Over volt-
age
F0003
Over tem-
perature
F0004
Short
circuit in
motor
F0006
Under
voltage
F0007
Speed
reference
error
F0016
Protective
earth fail-
ure
F0018
Internal
error
F0021
F0022
Power
supply
phase
fault
www.scanmaskin.com
 The potentiometer on the
control panel is damaged
 The internal temperature in
the inverter is above 120°C
(248°F). This could be caused
by faulty ventilation in the
electrical cabinet.
 The internal temperature in
the inverter is above 135°C
(275°F). This could be caused
by faulty ventilation in the
electrical cabinet.
 The cable to the motor has
been damaged
 The motor has been dam-
aged
 The cable to the motor has
been damaged
 The motor has been dam-
aged
 Water have entered the mo-
tor
 Inspect the potentiometer
 Replace if necessary
 Inspect the ventilation fans
 Inspect the filters to the fans
 Contact Scanmaskin Sweden
AB
Contact Scanmaskin Sweden AB
 Inspect the motor cable
 Inspect the motor connection
 Contact Scanmaskin Sweden
AB
 Inspect the motor cable
 Inspect the motor connection
 Contact Scanmaskin Sweden
AB
Contact Scanmaskin Sweden AB
ENGLISH
S
S
O
O
See A2001
See A2002
See A2009
E
E
See A2003
See A2006
E
E
See A2003