Adjustable Magnification
EyeZoom
and EyeZoom Mini
EyeZoom telescopes can transition magnification levels between 3x, 4x, and 5x power. EyeZoom Mini telescopes
can transition magnification levels between 2.5x and 3.5x power.
1. To change the magnification, grasp the black ridged portion of each telescope and turn it so the arrow aligns
with your preferred magnification level.
2. Ensure both telescopes are set to the same power.
OmniOptic
Telescope System
Telescope anchors will be installed in the carrier lenses of your loupe frame.
1. Insert a matching pair of telescopes into the anchors and they will be magnetically secured. Each telescope
is assembled with a key-slot to ensure it is properly aligned in the anchor.
2. To remove telescopes from the anchors, hold onto the loupe frame with one hand while pulling each
telescope out of its anchor. It will take reasonable force to disengage the magnetic interface.
3. When your loose telescopes are not being used, they should be stored in your loupe case.
8
INSTRUCTIONS FOR USE AND CARE
EyeZoom
OmniOptic
Technical Support/Customer Care: 1.800.369.3698 | Outside the U.S. or Canada Call Your Local Distributor
Orascoptic
Loupes
ErgoEdge / RDH Elite Edge Frame
The ErgoEdge model frame employs a unique feature that allows you to add or subtract 5 degrees of declination
(tilt) to your telescopes. Three different angle settings are displayed on the inside of each temple arm where
the arm interfaces with the front of the frame.
1. From the optical laboratory, the declination of your telescopes will be set to your prescribed angle and aligned
to the middle marking on each temple arm.
2. To change declination, loosen the angle control screw on each temple arm and rotate the arms upward or
downward to align the arm with a different marking on the frame front, then tighten the angle control screw
to lock the temple arm into that position.
• Top marking: increase declination (steeper angle)
• Bottom marking: decrease declination (shallower angle)
3. Both temple arms should be set to the same angle or clear vision will be compromised.
4. The nose pad may need to be adjusted after changing declination.
+5°
-5°
Angle Control Screw