Safety Notes

6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
6 Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
6 The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!

Installation Instructions

• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The plumbing codes applicable in the respective
countries must be oberserved.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
4
English
Wall mount see page 34
Ceiling mount see page 36

Technical Data

Operating pressure:
Recommended operating pressure
27378XXX / 27337XXX:
Recommended operating pressure
26466XXX / 26467XXX:
Recommended operating pressure
27384XXX / 27385XXX:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Dimensions (see page 31)
Flow diagram (see page 31)
Rain
RainAir
Operation (see page 39)
Cleaning (see page 40) and en-
closed brochure
Spare parts (see page 42)
max. 0,6 MPa
0,15 – 0,4 MPa
0,1 – 0,4 MPa
0,2 – 0,4 MPa
max. 60°C
max. 70°C / 4 min