Installation Instructions
Please Read Before Installing
Overview
The integral power supply of the HomeWorks 8-Series P5
Processor can power up to 350 LEDs. The power supply
included with the HomeWorks 4-Series P5 Processor can
power up to 150 LEDs. To power additional LEDs within a
HomeWorks system, an auxiliary 15 V-, IEC PELV / NEC
Class 2 rated power supply is required.
The T120-15DC-9-BL (100 – 240 V~), TE240-15DC-9-BL
(240 V~, Europe), and TU240-15DC-9-BL (240 V~, U.K.)
are plugged into a standard receptacle and can each power
an additional 150 LEDs.
HomeWorks RF seeTouch keypads (but not RF
slim-button keypads) can also be powered using an
auxiliary power supply. Each RF seeTouch keypad counts
as 20 LEDs toward the 150 LED limit. Each Hybrid Repeater
counts as 15 LEDs toward the 150 LED limit.
Panel-mounted power supplies that can each power
higher LED counts are available. Installation instructions
and technical specifications for these power supplies and
keypad LED counts are available www.lutron.com
Installation
WARNING - SHOCK HAZARD. May result in
serious injury or death. Turn off power at circuit
breaker before installing.
1. Cut the barrel plug off the end of the power supply wires.
2. Peel the wires apart.
3. Strip the insulation ½ in (13 mm).
4. Wire the power supply.
Wired Keypads / Hybrid Repeaters:
a. Connect the black power supply wire to Common.
b. Connect the black / white wire to +15 V wire going
to the additional keypads / repeaters only. DO NOT
connect the black / white wire to the +15 V on the
processor (pin 2) or to any other power supply.
See wiring diagrams Wired Keypads and Hybrid
Repeaters at right.
RF seeTouch Keypads:
a. Connect the black power supply wire to the black wire
on the keypad.
b. Connect the black / white power supply wire to the
white wire on the keypads. DO NOT connect the wires
to any other power supply. See wiring diagram
RF seeTouch Keypads on page 2.
5. Plug the power supply into a standard receptacle to
apply power.
Auxiliary Plug-in Power Supply
T120-15DC-9-BL 100 – 240 V~ 50 / 60 Hz 0.5 A
TU240-15DC-9-BL (U.K.) 220-240 V~ 50 / 60 Hz 200 mA
TE240-15DC-9-BL (Europe) 220-240 V~ 50 / 60 Hz 500 mA
043553
Rev. A
01/2021
Auxiliary Plug-In Power Supply
U.S.A.:
T120-15DC-9-BL
®
Wiring Diagrams
Wired Keypads
Connect the commons:
terminal 1 and black wire
on auxiliary power
supply.
DO NOT connect
To additional
+15 V (terminal 2)
auxiliary power
to the processor.
supplies
Hybrid Repeaters
DO NOT connect
+15 V (terminal 2)
to the processor.
U.K.:
Europe:
TU240-15DC-9-BL
TE240-15DC-9-BL
HomeWorks Processor
(4 Series processor shown)
To additional keypads
Keypad Link
Keypad 1
Terminal
Block
Keypad 20
Terminal
Block
To additional keypads
Black wire is Common
Black/white wire
is +15 V
HomeWorks Processor
(4 Series processor shown)
Hybrid Repeater Link
To additional Hybrid Repeaters
(Link 8)
(maximum 5 repeaters total)
Hybrid
Repeater
1 Terminal
Block
Black wire is Common
Black/white wire
is +15 V
150 LEDs maximum
Keypad 2
Terminal
Block
Keypad 21
Terminal
Block
150 LEDs maximum
Hybrid
Repeater
2 Terminal
Block