SIMPLIFIED INSTRUCTIONS FOR K500 WITH K-CRX
1° Connecting the motor and limit switch (done in the factory)
2° Connecting the accessories
3° Installing and adjusting the limit plate cams
Place the cams on the rack.
Tighten the two screws to lock them. How to finely adjust cam
intervention is explained below.
ITA
ESP ENG FRA GRE DEU RUS ARA THAI BUL FAR TUR
CAPACITOR
BROWN
BLUE
M
BLACK
MOTOR
BLUE
A
A
A
NO
NO
NC
NC
C
C
ANTENNA – Use an RG58 co-axial cable
ELECTRICAL SUPPLY
quick connector
Press. Insert the wire.
Release to lock it.
IMPORTANT
The motor is set to open towards the right.
If opening is to the left, the LSO and LSC wires on terminal block J2 and the V
and W wires on terminal block J7 must be reversed.
A* A
Jumper
COM-EDGE
A
A
A
Release the motor (turn the key counter clockwise until the limit is
reached without forcing) and move the gate by hand
Check when the cams are activated.
Note: The cams must press the electric microswitches before the
mobile part touches the mechanical stops.
HIN
CHI
NO
NC
A* A
S
C
S
A*A => A+A- Observe the polarity
of the photocells' electrical supply
POL HUN CEK KOR