Remove the front plate by unscrewing the two screws
4.5
on the upper edge of the cassette. Carefully bend out
and lift the plate out of the groove. Thread the cable
attachment through the hole in the backpiece. Firmly
screw the connector in the cassette section.Connect
the connector and tighten the cable entry by fixing
the small plate over the hole. Fit the front plate.
Set the cable in the clip above the arm when the
4.6
parallel arm is in its lower position. Install the
clamp protection using six screws.
Fit the temperature sensor box into the end of
4.7
the cassette. Bundle the temperature sensor
cable with a band above the clip. Remove the
protective hood from the pyrometer.
Note. On the IRT 402 XLNC, the pyrometer
should be located on the left cassette's right-
hand gable. The hose marked "1" and the pyrometer
should be mounted on the same cassette.
5.

Site

The area in which the mobile dryer is used should be
ventilated to such an extent that the solvent concent-
ration never rises above 50% of the lower explosion
limit.
Within a radius of 5 m around the mobile dryer, it is
forbidden to use or to store solvent-containing mate-
rials.
Avoid exposing the mobile dryer to paint fog, san-
ding dust and solvents.