9.4
Settings
Ch.
Overview
9.4.1
1 Select Language
9.4.2
3 Process Alarm
9.4.3
4 Temp Unit
9.4.4
5 Buzzer
9.4.5
7 Basic PIN Code
9.4.6
8 Short Dist lim.
9.4.7
9 Long Dist lim.
9.4.8
15 Temperature Ctrl
9.4.9
16 Disp. Contrast
9.4.10 18 Distance
9.4.11 23 Filter Time
9.4.12 25 Contin. Mode
9.4.13 36 Advanced PIN Code
9.4.14 37 Dist Unit
9.4.15 43 Advanced Code
9.4.16 44 Reset Prog. Settings
9.4.17 45 Reset Filter Timer
9.4.18 46 Statistics
9.4.19 47 Perform Self test
9.4.20 48 Program Time Scale
9.4.21 49 Proc. Alarm Temp.
9.4.1 1 Select Language
Use the up and down arrow keys to scroll through the
fourteen different languages (arranged alphabetically)
until the correct language appears. Press select to con-
firm.
If you accidently switch to a language that you don´t
understand, turn the main switch on while pressing the
"cassette in use" button. The dryer will then start up with
British English.
9.4.2 3 Process Alarm
Use the up and down arrow keys to set whether the
alarm is active or not. Press select to confirm. For alarm
sound settings, see "9.4.4 Buzzer".
9.4.3 4 Temp. Unit
°C and °F appear on the screen. Use the up and down
arrow keys to select the desired temperature unit. Con-
firm the selected unit by pressing select.
9.4.4 5 Buzzer
The sound effects can be muted/activated by using the
arrow keys to select no/yes. Press select to confirm.
9.4.5 7 Basic PIN Code
You can change the PIN code to prevent unauthorized
access to the basic settings, as described in table in
chapter 9.4. To do this use the up and down arrow keys
to change the first digit, press select to confirm. Continue
with the second, third and fourth digit. When completed
press select to confirm the new four digit PIN code.
8
8
9.4.6 8 Short Distance Limit
The original settings for the correct short distance limit is
available in
55 cm. You can change the value for the short distance
Basic Advanced
limit from 35 to 95 cm. Settings higher than 80 cm are not
x
recommended. Press select to confirm.
x
9.4.7 9 Long Distance Limit
x
The orginal settings for the correct long distance limit is
65 cm. You can change the value for the long distance
x
x
limit from 40 to 130 cm. Settings higher than 100 cm are
x
not recommended. Press select to confirm.
x
9.4.8 15 Temperature Ctrl
x
You can choose if you want to turn the temperature con-
x
trol (pyrometer) on or off permanently.
x
x
Note! If you turn the temperature control off in settings
mode you cannot activate it in program mode.
x
Temperature graphs and values will not be accessible
x
when this feature is turned off. Instead the software will
x
work with power levels, that is percentage of maximum
capacity.
x
x
9.4.9 16 Disp. Contrast
x
You can change the contrast of the display on a scale
from light to dark (25–55). Scroll between the values with
x
the up and down arrow keys and press select to confirm.
x
9.4.10 18 Distance
x
x
You can change the distance measuring between centi-
x
x
meters and text. If text is choosen the distance is indi-
x
cated on the display as "too close", "too far" or "correct". If
measuring fails "check distance manually" appears.
x
9.4.11 23 Filter Time
The default value is 400 working hours. After this time, the
filter replacement warning is displayed for filter change.
If the mobile dryer is placed in a dusty environment, it is
recommended to change more frequently.
Note! Keep in mind that if the filter is too dirty, the lamp
service life will be reduced as a result of impaired cooling.
To reset, see "9.4.17 Reset filter timer".
9.4.12 25 Contin. Mode
The continuous mode is for sales demo purposes.
For safety reasons and for minimizing unnecessary wear-
ing down of the dryer, this mode must only be used in
exceptional cases.
9.4.13 36 Advanced Pin Code
To change the code to your personal choice use the
up and down arrow keys to change the first digit, press
select to confirm. Continue with the second, third and
fourth digit. When completed press select to confirm the
new four digit PIN code.
Warning! Make sure that you remember the new code.
9.4.14 37 Dist Unit
This provides you with the opportunity to change unit
type between centimeters and inches.
EN
713687 rev 10