PURGE VALVE
INSTALLATION INSTRUCTIONS
DRAIN ALL AIR FROM THE VEHICLE RESERVOIRS
BEFORE YOU BEGIN THIS PROCEDURE.
1. Remove the three hex head screws and purge
valve cover shield and set aside.
2. Remove large snap ring.
3. With pliers pull out purge valve assembly
and discard.
4. Install large and small o-rings on the purge
valve assembly.
5. Lubricate the purge piston bore.
6. Insert new purge valve assembly in dryer
housing.
7. Install new snap ring.
8. Replace purge valve cover shield and install
the three hex head screws and torque to
40-55 in. lbs.
ONE-WAY CHECK VALVE OUTLET
INSTALLATION INSTRUCTIONS
DRAIN ALL AIR FROM THE VEHICLE RESERVOIRS
BEFORE YOU BEGIN THIS PROCEDURE.
1. Disconnect the dryer outlet line.
2. Remove outlet end cap.
3. Remove o-ring from end cap. Discard the seal
assembly, spring and o-ring.
4. Install new o-ring on outlet end cap.
5. Install new seal assembly and spring. Seal
assembly must be centered.
6. Thread outlet end cap into dryer body and
torque to 35-50 ft. lbs.
7. Reconnect outlet air line.
OPERATIONAL CHECKS
After repairs are completed and air lines are
reconnected, start the engine, build-up pressure to
100 psi, and shut off the engine. Check for air leaks
at the inlet and outlet of the dryer. Correct any
leakage problem. Restart the engine and build-up
pressure to cut-out pressure. At cut-out pressure
the dryer purge valve opens and immediately expels
a large volume of air, followed by a slow flow of air
lasting approximately thirty seconds. Check for
leakage to assure that the PURest Air Dryer will
operate properly.
A. Compressor Unloader Mechanism.
B. Governor.
C. Drain Cock and Safety Valve in first (supply)
reservoir.
D. All air connections leading to and from the
first (supply) reservoir.
ANOTHER PRODUCT FROM
Commercial Vehicle Systems
Haldex Brake Products Corporation
10707 N.W. Airworld Drive
Kansas City, MO 64153-1215
Phone: (816) 891-2470
Fax: (816) 801-4198
Haldex Limited
525 Southgate Drive, Unit 1
Guelph, Ontario Canada N1G 3W6
Phone: (519) 826-7723
Fax: (519) 826-9497
www.hbsna.com
Rev. 2/07 2.5M ART L31175 (Created 9/02)
Installation
Guide
L31175
Rev. 2/07
Installation Instructions
®
PURest
Air Dryer
Major Repair Kit (DQ6053)

Publicidad

loading

Resumen de contenidos para Haldex L31175

  • Página 1 Installation Instructions ® 6. Thread outlet end cap into dryer body and PURest Air Dryer torque to 35-50 ft. lbs. Major Repair Kit (DQ6053) www.hbsna.com 7. Reconnect outlet air line. Rev. 2/07 2.5M ART L31175 (Created 9/02)
  • Página 2 PURest TURBO-SAVER™ VALVE WARNING MAJOR REPAIR KIT CONTENTS INSTALLATION INSTRUCTIONS When working on air system components the following precautions (DQ6053) DRAIN ALL AIR FROM THE VEHICLE should be observed. RESERVOIRS BEFORE YOU BEGIN THIS PROCEDURE. TURBO-SAVER™ VALVE 1. Stop engine when working under a 1.
  • Página 3 Revise en busca de fugas para asegu- L31175 Rev. 2/07 4. Instale los anillos de empaque grande y pequeño en el rarse que el secador por aire Pure Air Plus funcionará...
  • Página 4 CONTENIDO DEL JUEGO DE ADVERTENCIA VÁLVULA TURBO-SAVER™ REPARACIÓN MAYOR INSTRUCCIONES PARA LA Al trabajar con componentes que se basan (DQ6053) INSTALACIÓN en sistemas de aire, deben observarse las PURest siguientes precauciones. DRENE TODO EL AIRE DE LOS TANQUES DEL VEHÍCULO ANTES DE INICIAR ESTE PROCEDIMIENTO. 1.

Este manual también es adecuado para:

Dq6053