Eikon TACTIL
21520
Home automation control device, 4 programmable buttons for managing two
functional units for single loads or scenarios, to be completed with a label and
Eikon Tactil cover plate - 2 modules.
The device is composed of two touch switches that, via the bus, enable controlling relay
actuators, dimmer actuators and roller shutter actuators. These switches can also be configured
in the speaker system to switch on and adjust the volume, change song and source, activate
audio monitoring and the sleep function; they can also be used individually for calling up
scenarios.
The device is to be completed with the Eikon Tactil cover plate; the buttons however react
to mechanical pressure even without fitting the cover plate so the configuration and the first
operating test can be performed in this condition.
FEATURES.
• Rated supply voltage Busbar: 29 V
• Current draw from Bus with all LEDs off: 17 mA
• Maximum current draw from Bus with all LEDs on or at low brightness, white: 35 mA
• Terminals: TP BUS
• Operating temperature: -5 °C to +45 °C (indoor)
OPERATION.
• Device settings:
- colour: all the LEDs are changed at the same time by choosing the colour from a list or by
setting the RGB coordinates using the special control panel menu
- touch sensitivity (i.e., the amount of pressure required to actuate a command)
- buzzer on/off
- behaviour of the LEDs with the device on standby (off or with low brightness)
• Possible functions of the buttons:
- ON/OFF switch
- roller shutters control
- dimmer control
- activation of 4 scenarios
- switching on/off and volume control
- changing song and source
- audio monitoring
- sleep
• Proximity function:
- when the user draws her hand near, the device goes into "normal" operation and the LEDs
light up brightly.
- if after 10 seconds no action is carried out, the device will go back onto standby and the
LEDs will switch off or reduce their brightness.
The illuminated icons guide the user in choosing the commands as they identify the
points where any pressure will trigger the device.
These icons can be customized with symbols and stickers to be affixed on the
corresponding buttons (art. 21847).
• Cover plate cleaning function: the device recognizes simultaneously pressing multiple keys
due to wiping with a cloth so no actions are carried out unless you dwell too long on the same
area of the cover plate.
CONFIGURATION.
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE THE By-me
SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE CONTROL UNIT.
The configuration operations must be carried out without the cover plate in order to access the
configuration button and the buttons for selecting the functional unit.
• Functional units: 2 buttons, each functional unit can belong to at most 4 different groups
• Selection of the functional unit in the configuration phase:
- press the configuration button and then the desired button to select the relevant functional
unit.
- configuration starts when the red LED comes on and ends when it goes out.
INSTALLATION RULES.
Installation should be carried out by qualified personnel in compliance with the current
regulations regarding the installation of electrical equipment in the country where the products
are installed.
• The device can be installed on Eikon Tactil cover plates with 2, 3 and 4 modules; by using cover
plates with 4 modules you can install 2 devices art. 21520. In the case of cover plates with
3 or 4 modules use the appropriate blank module art. 21041 to close the unused modules.
• When installing with a BS 5M cover plate (2+blank+2), thus on the mounting frame art. 20609,
the device cannot be installed in the central module of the mounting frame; this module should
be closed by using the blank module art. 21041 (for details, see SC-Card on www.vimar.com
-> Products -> Product Catalogue at the article code).
• On the same cover plate used for art. 21520 it is not possible to install touch devices powered
by mains voltage (art. 21174, 21119, 21122, 21134).
REGULATORY COMPLIANCE.
EMC directive. Standards EN 50491, EN 60669-2-5.
49400576B0 05 1801

FRONT AND REAR VIEW

Icon illumination LED
Configuration
button
Configuration
LED
Icon illumination LED
INSTALLATION
1. Customizing buttons with labels
2. Closing gaps with the blank module art. 21041
3. Attaching the Eikon Tactil cover plate
RAEE - Informazione agli utilizzatori
If the crossed-out bin symbol appears on the equipment or packaging, this means the product
must not be included with other general waste at the end of its working life. The user must take
the worn product to a sorted waste center, or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation) to
retailers with a sales area of at least 400 m
waste collection for the environmentally friendly disposal of the used device, or its subsequent
recycling, helps avoid the potential negative effects on the environment and people's health, and
encourages the re-use and/or recycling of the construction materials.
TP Busbar terminals
Attach the plate so that the central contacts
perfectly match those of the control appliance
21520 and wait for the device to return to
standby mode before you start using it.