Problem
Solution
Portable Compressor will not
• Make sure the compressor power switch is in the on position.
inflate
• Make sure the SureFit
valve stem when attempting to inflate tires; or that the nozzle adapter
is securely screwed into the SureFit
properly into the item to be inflated on all other inflatables.
• The compressor may be overheated. Press the compressor power
switch to turn the compressor off. Restart after a cooling down period
of approximately 30 minutes.
• Check that unit has a full charge. Recharge unit if necessary.
CARE AND MAINTENANCE
All batteries lose energy from self-discharge over time and more rapidly at higher temperatures. When the unit
is not in use, we recommend that the battery is charged at least every 30 days.
Never submerge the unit in water. If the unit gets dirty, gently clean the outer surfaces of the unit with a soft cloth
moistened with a mild solution of water and detergent.
There are no user-replaceable parts. Periodically inspect the condition of adapters, connectors and wires.
Contact manufacturer to replace any components that have become worn or broken.
Battery replacement/disposal
BATTERY REPLACEMENT
The battery should last the service life of the unit. Service life is dependent on a number of factors including but
not limited to the number of recharge cycles, and proper care and maintenance of the battery by the end user.
Contact manufacturer for any information you may need.
SAFE BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be
disposed of properly. Recycling is required. Failure to comply with local, state and federal
regulations can result in fines, or imprisonment.
Please recycle.
WARNINGS:
• Do not dispose of the battery in fire as this may result in an explosion.
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting
(shorting can result in injury or fire).
• Do not expose battery to fire or intense heat as it may explode.
12 volt DC charger plug fuse replacement (may be sold separately)
The fuse in the plug end of the 12 volt DC charger protects the adapter's charging circuit. If the 120 volt AC charger
operates, but the DC charging adapter does not, then this fuse may be opened (blown).
To replace the fuse:
1. Unscrew the end cap of the DC plug (counterclockwise).
2. Remove spring center contact and fuse.
3. Check fuse with a continuity checker.
4. If blown, locate a replacement 8 amp fuse.
5. Replace the fuse, spring, contact and end cap.
6. Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.
7. Test for proper operation of the 12 Volt DC Charging Adapter.
ACCESSORIES
Recommended accessories for use with this unit may be available from the manufacturer. If you need assistance
regarding accessories, please contact manufacturer at 1-877-571-2391.
WARNING: The use of any accessory not recommended for use with this appliance could be hazardous.
PPRH5B_ManualENSP_082018.indd 12-13
nozzle connector is securely screwed on to the
®
nozzle connector and is inserted
®
12
SERVICE INFORMATION
Whether you need technical advice, repair, or genuine factory replacement parts, contact the manufacturer at
(877) 571-2391.
FULL ONE-YEAR WARRANTY
The manufacturer warrants this product against defects in materials and workmanship for a period of ONE (1)
YEAR from the date of retail purchase by the original end-user purchaser ("Warranty Period").
If there is a defect and a valid claim is received within the Warranty Period, the defective product can be
replaced or repaired in the following ways: (1) Return the product to the manufacturer for repair or replacement
at manufacturer's option. Proof of purchase may be required by manufacturer. (2) Return the product to the
retailer where product was purchased for an exchange (provided that the store is a participating retailer).
Returns to retailer should be made within the time period of the retailer's return policy for exchanges only
(usually 30 to 90 days after the sale). Proof of purchase may be required. Please check with the retailer for their
specific return policy regarding returns that are beyond the time set for exchanges.
This warranty does not apply to accessories, bulbs, fuses and batteries; defects resulting from normal wear and
tear, accidents; damages sustained during shipping; alterations; unauthorized use or repair; neglect, misuse,
abuse; and failure to follow instructions for care and maintenance for the product.
This warranty gives you, the original retail purchaser, specific legal rights and you may have other rights which
vary from state to state or province to province. This product is not intended for commercial use.
Please complete the Product Registration Card and return within 30 days from purchase of the product to:
Baccus Global LLC, One City Centre, 1 North Federal Highway, Suite 200, Boca Raton, FL 33432. Baccus
Global LLC, toll-free number: 1-877-571-2391.
SPECIFICATIONS
Boost Ampere:
450 instantaneous cranking amps
Battery Type:
Sealed, high energy density, AGM, lead-acid, rechargeable,
maintenance-free, 12 volt DC
Area light:
3 white LEDs
USB port:
5Vdc, 2,000mA
DC accessory outlet:
12Vdc, 5A
Dual 120V AC outlets:
120Vac, 60Hz, 500W continuous
Compressor
maximum pressure:
120 PSI
Imported by Baccus Global LLC, One City Centre, 1 North Federal Highway, Suite 200, Boca Raton, FL 33432
www.Baccusglobal.com 1-877-571-2391
13
8/20/2018 6:10:12 PM