4.
Important Notes
• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
• All rights reserved to make technical alterations.
5.
Application
PROTRONIC - A3000 open opto-electronically controlled washing-unit fitting DN 15
for in-wall installation, for connecting to premixed warm or cold water.
With facility for externally controlling options such as fittings settings and
communication via ECC function controller.
Control functions:
• Hygiene flushing (10 seconds), 24 hours after last usage
• Safety shut-off after 5 minutes duration reflection
Additional functions with ECC function controller (Ethernet):
• Automatic thermal disinfection according to DVGW work sheet W 551 as well as
safety switch-off
• Cleaning system shut-down
6.
Technical Specifications
Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculation flow rate:
Volumetric flow:
Operating voltage:
Power consumption:
Communication:
Type of protection:
1.0 bar
1–5 bar
10 bar
0.10 l/s
0.10 l/s for 3 bar flow pressure
24 V DC
2.5 W
Ethernet via ECC function controller
IP 68
5