Opening of housing bracket
Housing cover
360PROtect
TM
Masking Detection lenses
Filter (window)
Bracket cover
Removal from mounting surface
tamper contact adjustment screw
Pin assignment and output event selection
Pin Function
Description
Settings
1
GND
GND supply
2
+
V+ supply voltage
10.5 - 30 V
, 24 V
±15% auto-sensing
DC
AC
3
RS-485 - B
RS-485 bus
4
RS-485 - A
Following events lead to alarms listed in the table, which can be disabled/enabled via
ADPRO PRO E-TOOL-Software (Default Setting = bold):
• Masking detection (instead of `ALARM´+´FAULT´)
• Alarm (IR)
5
• Alarm medium range (IR); alarm long range (IR), alarm short range (IR) *
Free programmable
• Alarm creep zone channel 1 (CH1), creep zone alarm channel 2 (CH2)
output 5
• Tamper alarms (cover open, detector alignment, bracket tamper contact
OUT 5
• Hardware information (e.g power failure)
(For H-versions)
• Info alarms (pulse count near, pulse count far, power on)
6
* Multi-channel detectors only
• Masking detection (instead of `ALARM´+´FAULT´)
• Alarm (IR)
7
• Alarm medium range (IR), alarm long range (IR), alarm short range (IR) *
Free programmable
• Creep zone alarm per channel
output 4
• Tamper alarms (cover open, detector alignment, bracket tamper contact
OUT 4
• Hardware information (e.g. power failure)
(For H-versions)
• Info alarms (pulse count near, pulse count far, power on)
8
* Multi-channel detectors only
• Alarm (IR)
• Alarm medium range (IR), alarm long range (IR), alarm short range (IR) *
9
• Alarm creep zone (CH1+CH2) - non-H-versions
Out 1
• Masking detection (together with intrusion FAULT)
Alarm output
(ALARM)
• Power on
10
* Multi-channel detectors only
11
AE
End-of-line alarm
Support point for end-of-line cabling; refer to Fig. „Terminal block and pin assignments"
• Power failure
12
• Masking detection (together with intrusion ALARM) - non-H-versions
• Heat system error - H-versions
Out 3
Fault alarm output
• Flash problems
(FAULT)
• Wrong model selected; refer rotary switch mapping
13
• Power on
• Cover open
14
Out 2
• Alignment
Tamper alarm output
(TAMPER)
• Tamper contact of mounting bracket
15
16
TE
End-of-line tamper
Support point for end-of-line cabling; refer to pin assignment
Opening of housing
Bead
lens
Telescopic sight mounting block
(comes with alignment telescope)
Notch
Locking screws
Compliant seal
Application of iCommission on swivel bracket
iCommission
Rotary switch position-detector
model mapping
Pin Model
Description
1
PRO E-45
2
PRO E-18W
3
PRO E-18
4
PRO E-30
Recommended fixing
5
PRO E-40
d
8 mm
0
6
PRO E-45D
h
50 mm
1
7
PRO E-100
L
40 mm
D
A
PRO E-45H
with heater
d
4.5 - 5 mm
S
B
PRO E-18WH with heater
d
47.5 mm
C
PRO E-18H
with heater
bracket guide
L
90 mm
D
PRO E-45DH with heater
S
E
PRO E-100H
with heater
F
2 Nm
L
S
F
d
d
0
s
d
L
bracket guide
D
h
1
Terminal block and pin assignments
End of Line
Cabling
R
Side covers w/ breakout
cuts for hose clamps
Drilling holes dimensions (use this template for drilling)
End of Line
Cabling
R
A
B

Publicidad

loading