PET Series | Stainless Steel Pressure Tanks
USE OF THE MANUAL
This use and maintenance manual is an integral part of the equipment
and must be easily available to the staff in charge of its use and main-
tenance. The user and the personnel in charge of maintenance must be
aware of the contents of this manual.
Read the manual carefully before starting ANY ACTIVITY involving
the equipment, including its handling.
THE ORIGINAL CONFIGURATION OF THE EQUIPMENT MUST
NOT BE CHANGED.
Upon receiving the equipment make sure that:
The supply corresponds to the order specifications.
In case of non-compliance, inform our Technical Service
immediately.
ALL RIGHTS ARE RESERVED. THE REPRODUCTION OF ANY PART OF
THIS MANUAL, IN ANY FORM, IS STRICTLY FORBIDDEN WITHOUT
PRIOR WRITTEN AUTHORIZATION OF THE MANUFACTURING
COMPANY.
WARRANTY
All the products of ANEST IWATA have a one-year warranty from
invoice date, unless otherwise stated in writing. The warranty covers
all manufacturing faults and material defects.
Any spare part replacement or repair operation is covered only if it is
carried out by our technicians at our servicing shops.
The warranty covers no intervention of our technicians during installa-
tion or dismantling operations.
If for practical purposes one of our technicians is sent to the premises,
the time plus extra for travelling and expenses will be invoiced at
current prices. Our warranty does not cover direct or indirect damage
to people or property caused by our equipment. It covers no repair
operations carried out by the customer or by a third party, either.
THE WARRANTY DOES NOT COVER:
Damage or breakdown caused by improper use or assembly.
Damage or breakdown caused by the use of spare parts different from
the original or recom mended ones.
Damage or breakdown caused by bad preservation.
Components subject to wear (described in the spare parts list).
WARRANTY FORFEITURE:
In case of delayed payment or other breaches of contract.
Whenever changes or repairs are carried out on our equipment without
our prior authorisation.
Whenever the serial number is damaged or removed.
When the damage is caused by improper use or functioning, or if
the equipment falls, is bumped or by other causes not due to normal
working conditions.
Whenever the unit is disassembled, tampered with or repaired without
the authorisation of ANEST IWATA.
All repair interventions carried out under warranty do not interrupt its
duration.
1. SAFETY WARNING
Be sure to read and understand this instruction manual.
The operator shall be fully conversant with the requirements
stated within this instruction manual including important warn-
ings, cautions and operations.
Wrong operation (mishandling) can cause serious bodily injury,
death, fire or explosion.
SAFETY FACTOR
WEAR PROTECTIVE GEAR: During painting, be sure to wear protective
gear such as glasses, mask or gloves to avoid serious injury caused
by paints or solvents which might enter your eyes or you might inhale.
BE CAREFUL ABOUT VENTILATION: Use it in a well-ventilated area.
Painting or cleaning in a narrow area with insufficient ventilation can
cause organic solvent intoxication or explosion due to sprayed mist of
paint or solvent which catches fire. If you feel any abnormality during
operation, consult a medical doctor immediately.
CONTACT IS FORBIDDEN: If paint leaks, never try to stop it
by hand. In that case please proceed as follows:
Follow the instructions about release pressure proce-
dure, provided in section 4.2.
Check the leakage causes.
Replace or repair the faulty component.
BE CAREFUL ABOUT BODILY INJURY: Paint can enter
human body directly through eyes, mouth or skin. It is
very dangerous. If you feel any abnormality or receive
any injury, consult a medical doctor immediately.
LIMIT OF FLUID TO BE USED: Do not use it for food products.
KEEP AWAY FROM ORIGINS OF EXPLOSIONS OR FIRES:
Never use near sparks or open fire.
Especially the following will cause fire:
Open flames such as cigarettes, pipes.
Electric goods such as stoves, lamps or heaters.
CONNECT GROUNDING: Securely ground pressure tank,
spray gun, workpieces and containers containing paint
or solvent. Be sure to use ground wire set supplied with
pressure tank.
Connect it to ground to have continuous grounding.
Insufficient grounding will cause explosion or fire if
exposed to a spark of electricity.
BE CAREFUL ABOUT EXPLOSION: Be sure to use pressure
tank at less than max. fluid working pressure. Use at
more than max. fluid operating pressure can cause explosion
of pressure tank resulting in great danger. Securely connect
hose to avoid leak and looseness. If hose is disconnected
during operation, hazardous hose movement and paint
ejection will cause severe bodily injury.
IMPORTANT : Never alter the equipment.
When you replace parts, be sure to use our genuine
parts. If not done, it can cause insufficient performance
or failure.
Do not use with corrosive liquids (except for PH6-8)
Install or keep pressure tank free from rain or splashes. If not
done, it can cause pressure tank failure.
Install pressure tank on a horizontal surface
Install pressure tank free of paint mist. Attached paint mist
etc., can cause pressure tank failure.
WE SHALL NOT BE RESPONSIBLE FOR ANY INJURY OR DAMAGE
CAUSED BY DISREGARD OF WARNINGS, CAUTIONS OR INSTRUCTIONS.
2. TANK DESCRIPTION
The equipment described in this manual is a Stainless Steel
Pressure Tank PET model for paint spraying systems. The pressure
inside the tank allows spraying the paint with a pressure between 0
and 7 bar (700 kpa). The possibility to adjust the product pressure
improves the quality of applicationand facilitates the flow of highly
viscous products.
EN
3