WArNINg:
ELEcTrIcAL ShOck hAzArD.
Turn off power at the main power source before installing
a coffee Brewer Water Valve. DO NOT restore electrical
power to the unit until the coffee Brewer Water Valve is
properly installed and the compartment cover is secured
with the retaining screws supplied with the unit.
1. Disconnect the power source to the unit.
2. Turn off the water supply.
3. Remove the compartment cover to gain access to the
water valve. Keep any retaining screws.
4. Remove the inlet and outlet hoses from the water valve.
Place hoses into a bucket to catch any water drainage or
water from the fill tank.
5. Disconnect the wiring plugs from the water valve coil.
6. Remove any screws retaining the valve and remove the
valve. Keep the mounting screws.
7. Put the new water valve into the original valve location.
8. Secure the water valve with the mounting screws.
9. Connect the wiring plugs to the water valve coil.
10. Reconnect the hoses to the water valve. Connect the
correct hose to the inlet and outlet sides of the valve.
11. Re-attach the compartment cover and secure the cover
with the retaining screws.
12. Reconnect the electrical power.
13. Turn the water supply on and check for proper operation.
191 E. North Avenue
Carol Stream Illinois 60188 USA
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
HVACCustomerService@Invensys.com
COFFee BreWer WATer VALVeS
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7294
TechnicalService@Invensys.com
INSTALLATION DATA
Uni-Line
and Robertshaw
are trademarks of Robertshaw
®
®
Controls Co. its subsidiaries and/or affiliated companies.
All other brands mentioned may be the trademarks of
their respective owners.
GS-56 SerieS
GS-56
www.Uni-Line.com
www.InvensysControls.com
©2014 Robertshaw Controls Co.
03/14 – 352-00179