Hydor Prime 10 Guía De Usuario página 4

Ocultar thumbs Ver también para Prime 10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
Contents
English
pag 7
Deutsch
pag 10
Français
pag 13
Español
pag 16
Italiano
pag 19
Nederlands
pag 22
Português
pag 25
Svenska
pag 28
Polski
pag 31
Magyar
pag 34
pag 37
6
PRIME external lter
Dear Fishkeeper,
thank you for choosing this quality product. PRIME is the rst external self-priming
power lter with automatic priming chamber equipped with safety tap. Please
read the instructions carefully, you will then appreciate the lters unique features
and characteristics and you will be able to use PRIME at its best.
Description -Fig. 1-
PUMP ASSEMBLY
A.
A1 Sloping rotatable ttings
A2 Tap
A3 Safety locking button
A4 Clip
A5 Impeller assembly
A6 Fixed O-ring (for models Prime 20
and Prime 30 only)
A7 Pump chamber
A8 Priming chamber
VALVE TAPS
B.
FILTER UNIT
C.
C1 Filter media container
C2 Filter body
C3 Antislip rubber feet
Installation
Attention: always disconnect all electrical equipment from the electricity supply, installed
both inside and outside your aquarium, before putting your hands in the water and be sure
that the voltage of the mains corresponds to the voltage shown on the label of the unit.
Whilst priming the lter, PRIME must be located below the aquarium level -Fig. 2-. If you
wish to place the unit at the side of the aquarium, you must do so only after priming it.
Preparing the lter
Choose the most suitable location for the inlet and outlet systems and install them with the
locking nuts on the outside of the tank. It is suggested that the intake and outlet units should
be mounted close to the rear corners, at opposite ends -Fig. 3-.
The suction unit can be lengthened by inserting the extension tube between the priming clip
and the pre lter, cutting it to the required size. If the aquarium does not need an extension
tube, connect the pre lter directly to the priming clip
Adjust the maximum height of the outlet unit as indicated by "MAX. WATER LEVEL" and cut
o any excess tubing -Fig. 4-. Both the connector tubes must be xed to the walls of the tank
by means of the suction cups provided.
Cut the exible tubes to the most convenient length, the cut must be at 90° to the tube wall
and as neat as possible. Connect the tubes to the inlet and outlet systems, as straight as
possible without kinks or twists, xing them with the locking nuts following the procedure
as shown in -Fig. 5-.
For the rst 24 hours of operation it is advisable to check the closure of the connections and
of the nuts.
Mounting the spray bar (for US version only)
On the delivery unit, it is possible to apply the spray bar, a sort of hollow tube that improves
oxygenation -Fig. 13 - available only on North American models and optional in the rest of
the world.
Insert the plug into the opposite end of the tube of the spray bar.
Cut the inside part of the delivery unit so that the spray bar is positioned near the surface
of the water.
Connect the elbow coupling to the delivery unit and then to the tube.
INTAKE UNIT
D.
D1 Collector tube
D2 Extension tube
D3 Locking nut
D4 Priming clip
D5 Strainer
OUTLET UNIT
E.
E1 Collector tube
E2 Nut
E3 Multi-directional di user
SPRAY BAR
F.
F1 Support tube
F2 Elbow coupling
F3 Suction clip
F5 Plug
FLEXIBLE PIPES
G.
English
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Prime 20Prime 30

Tabla de contenido