Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and
standards. Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting
1.
Unplug the unit.
2.
Cut a 2³/
" x 1³/
" hole in a wall at a convenient
8
8
location for the wall control. Route a cable (type
22/4) for the wall control from the unit to this
hole.
3.
Temporarily place the wall control over the hole
and mark both mounting screw hole positions.
4.
Remove the wall control, drill both screw holes
(3/16" Ø) in the wall and insert the included wall
anchors.
5.
Strip the end of the cable to access the wires.
NOTE: Although this is a 4-wire cable, only 3 of them will be used for connection.
6.
Strip the end of 3 wires. Connect the wires to the terminals, regardless of
the wire color: one wire to "OL'', another one to "OC'' and one to "I''. Note
which wire color has been chosen for each terminal. See illustration below.
VT11W P
First wire
OL
Fourth wire
(NOT USED)
VE0374
VT11W WALL CONTROL
READ AND SAVE THESE INSTRUCTIONS
means to prevent power from being switched on accidentally.
Always wear safety glasses and gloves while performing these instructions.
Ø 3/16" , typ.
VC0125A
B
USH
UTTON
R
EAR VIEW
Second wire
Third wire
OC
I
WARNING
7.
Mount the wall control to the wall.
8.
Perform the electrical connection to the terminal connector of the unit,
as shown below. For more details, refer to the installation manual of the
ventilation unit.
NOTE: To avoid miswiring, refer to the notes about the color of the wires taken
on step 6.
Y
W Gf
9.
Plug the ventilation unit and test the wall
control (A). The LED indicator will turn on
to indicate that the unit is working. Push the
button again to turn the unit OFF. UNIT WILL
REMAIN POWERED, but will not work.
NOTE: Keep in mind that the unit is designed to
ventilate at the best time of the day and may
not continuously ventilate even though the
wall control LED indicator is ON.
VC0126
VT11W P
R
STB
STB
G
R
C LED
IN
out
B
A
VC0127
B
USH
UTTON
EAR VIEW
99046049 rev. 01

Publicidad

loading

Resumen de contenidos para Broan VT11W

  • Página 1 VT11W WALL CONTROL READ AND SAVE THESE INSTRUCTIONS ⚠ WARNING Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.
  • Página 2 CONTROL MURAL VT11W LEA Y GUARDE ESTAS INSTRUCCIONES ⚠ ADVERTENCIA Riesgo de descarga eléctrica. El cableado eléctrico debe ser realizado por personal cualificado, de acuerdo con todos los códigos y normas aplicables. Antes de conectar los hilos, desenchufe el aparato o apague la alimentación en el tablero de servicio y bloquee los medios de desconexión para evitar que se conecte la corriente accidentalmente.