NSTALLATION AND
The illustrations in this document are generic; your control appearance may be slightly different from the ones shown.
Electrical wiring must be done by qualifi ed personnel in accordance with all applicable codes and standards.
Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting means
to prevent power from being switched on accidentally. Always wear safety glasses and gloves while performing
these instructions.
INSTALLATION
Unplug the ventilation unit.
NOTE: If the control is to be installed in an electric box, go to step
Cut a 2
7
/
" x 1¾" hole in a wall, at a
8
convenient location for the control.
Route a cable (type 22/4) for the
control from the unit to this hole. See
figure at right.
Temporarily place the control over the
hole and mark both mounting screw
hole positions.

Remove the control, drill both screw
holes (3/16" Ø) in wall and insert the wall
anchors (included).

Strip the end of the cable to access the 4 wires (about 3"). Strip the
end of each wire (about 1/4"). Connect the wires to the terminals,
regardless of the wire color. Note which wire color has been
chosen for each terminal. See illustration below.
VC0236

Mount the control to the wall.
U
G
A
SER
UIDE FOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
!
Ø 3/16", typ.
VC0213A
12V
D-
D+
Gnd
VC0214
C
UTOMATIC
ONTROL

Perform
the
electrical
connector of the unit, as shown below. For more details, refer to
the installation manual of the ventilation unit.
NOTE: To avoid miswiring, refer to the notes taken at step
match the wire color with the right terminal.
.
VC0235
Plug the ventilation unit and test the wall control.
HOW TO USE THE CONTROL
VC0184
RECIRC: Recirculate air inside the house at MAX speed. Not
available on all units.
INT: Within a one hour period, the system will operate in MIN
speed for 20 minutes.
MIN/MED/MAX: Continuous exchange ventilation at selected
speed.
Press the TURBO button to get 4 hours of ventilation in MAX
speed. The TURBO indicator will light up. Once the 4-hour
period is done, the system will operate according to the
previous setting.
• Press the AUTO button to let the system operate according to
outdoor temperature. The AUTO indicator will light up.
If the maintenance indicator is lit, it means that the filter
needs to be cleaned or replaced. Once the filter is cleaned or
replaced, press the AUTO button for five seconds to reset the
maintenance indicator. If the maintenance indicator flashes, the
LCD screen on the unit will give the error code. Refer to the
Troubleshooting section in the ventilation unit user guide for
more information.
(
.
)
PART NO
VAUTOW
connection
to
The main button works following this
sequence:
• Click 1 = RECIRC (if available)
• Click 2 = INT
• Click 3 = MIN
• Click 4 = MED
• Click 5 = MAX
• Click 6 = OFF
• and so on
The indicator lights up as per the selected
mode.
the
terminal
to
12V
D-
D+
Gnd
23841 rev. 01

Publicidad

loading

Resumen de contenidos para Broan VAUTOW

  • Página 1 UIDE FOR UTOMATIC ONTROL PART NO VAUTOW READ AND SAVE THESE INSTRUCTIONS The illustrations in this document are generic; your control appearance may be slightly different from the ones shown. WARNING Electrical wiring must be done by qualifi ed personnel in accordance with all applicable codes and standards.
  • Página 2 ANUAL DEL USUARIO Y DEL INSTALADOR PARA EL CONTROL AUTOMÁTICO DE PIEZA VAUTOW LEA Y GUARDE ESTAS INSTRUCCIONES Las ilustraciones en este documento son generales; su control puede tener un aspecto ligeramente diferente. ADVERTENCIA El cableado eléctrico debe ser realizado por personal cualifi cado, de acuerdo con todos los códigos y normas aplicables.