DIAGRAM
INSTALLATION
There are two brackets included, remove the two brackets from the RO membrane housing and install to the
wooden plate or onto a wall, Now install the valves.
Now install the RO membrane. Use the filter wrench to unscrew the RO housing head, before doing this, you need
to pull out the water tubing.
1. Remove the blue clip on the water fitting
2. Press down the blue clip
3. Pull out the tubing
Peel off the RO membrane plastic bag, and take out the membrane and insert the RO membrane to the bottom
of the RO housing with the membrane black ring is on the top​
Screw back the RO membrane head, and put the tubing and the clip back on.