LaserLiner 082.326A Manual De Instrucciones página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
3. Brush deep-insertion electrode
for moisture measurement in a homogeneous building material.
Contact is established by the brush tip.
4. Flat deep-insertion electrode (insulated, 1 mm flat)
for targeted moisture measurement in the concealed structure levels
of multi-layer wall or ceiling structures. Electrodes can, for example,
be inserted through edge strips or at the wall-ceiling transition.
2
Connecting deep electrodes with connecting cable
1.
3
Applying deep electrodes
The spacing of bore holes should be between 30 and 50 mm and be ø 8 mm
DampMaster Compact
for brush electrodes. After boring the hole, wait for about 30 minutes to allow
moisture driven out of the hole by drilling heat to return to its original value.
Otherwise measurement results could be falsified.
EU directives
This device complies with all necessary standards
for the free movement of goods within the EU.
DampExtension Compact set
2.
DampMaster Compact
3.
05
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido