INSTALLING YOUR REPLACEMENT
FILTER SYSTEM
1. Your air purifier will automatically tell you when its time to change your filter. An
icon on the control panel will illuminate after 2500 hours of purification has been
reached.
2 . Place the 4-sided combination H13 HEPA/Active Carbon filter on a sturdy
flat surface.
3. Slide the removable, reusable metal pre-filter that you have washed and dried
into the slots on all 4 sides of the replacement H13 HEPA/Active Carbon filter.
4. Slide the new 4-sided filter system into the back of the unit until you feel resis-
tance.
5. Make sure your air purifier is plugged in and powered up.
YOU WILL NOW NEED TO RESET THE FILTER INDICATOR.
6. Reset the filter indicator light by pressing and holding down the night light
button for 3 seconds. This will reset the filter indicator light.
MAINTENANCE AND REPLACEMENT
OF FILTERS AND UV-C LIGHT
The H13 high-grade HEPA filters could be vacuumed as needed in order for the air
purifier to perform at its best. If the air purifier contains dust or pet dander, it's best
to clean the removable, reusable metal pre-filters more often than once a month to
maintain 2,500 hours of filter life. Always unplug your air purifier from the electrical
outlet before replacing or removing any filters or replacing the UV-C bulb.
Step 1. Filter Cover Panel:
The Purxium Air Purifier takes in and purifies air on all 4 sides.
To remove filters contained in the unit, you will remove the filter cover
panel located in the back of the air purifier. Press the button located on
top of the panel to release it from the base of the unit.
Step 2. Pre-Filters and HEPA H13 Filtration Set:
You will now see the pre-filter and HEPA H13 and active carbon filters
that you will remove from the unit by placing your fingers
on the left and right side of the filter and pulling straight out.
The filters are a complete set. The pre-filters may be removed
by pulling them up through the slots.
Step 3. UV-C Light:
Follow Steps 1 and 2 for removing filters. At the base of the unit, there is
one screw that hold the cover to the UV-C bulb compartment. Remove
the screw with a screwdriver and carefully remove the UV-C light bulb.
Replace with new a UV-C light bulb. The UV-C light bulb should be
replaced at 10,000 hours of use. Contact Cuisinart customer service for
your replacement UV-C light tube.
WARNING: Skin or eye damage may result from directly viewing the light
produced from this lamp in this apparatus. Always disconnect before relamping or
servicing. Replace lamp with Lamp Model No.: Z138, manufactured by Zhangzhou
Yingguang Electronic Technology Co., Ltd.

FEATURES AND SPECIFICATIONS

Note: The UV-C light contains mercury, which is a hazardous material. Please use
gloves when removing the bulb, place into a plastic bag and drop off at a recycle
facility near you.
Our H13 High Grade HEPA filter captures up to 99.9% of airborne particles
0.1 Micron or larger including bacteria and various contaminants as well as dust,
pollen and odors from cooking, smoke, pets and VOC's. The CAP-1000 quiet DC
motor has a 3-stage filtration system that purifies air in an up to 1,000-sq. ft. area
two times every hour or 500-sq. ft. area four times every hour.
5