Westinghouse W-031 Instrucciones De Instalación página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MOUNTING AND WIRING INSTRUCTIONS
CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal
between the fixture and the mounting surface by using silicone or similar caulking.
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These
fixtures meet all UL specifications.
1. Turn off power at circuit box to avoid possible electric shock.
2. Remove cap nuts (A) from back plate (B) and remove universal mounting plate or cross
bar (C) (see fig. 1).
3. Secure universal mounting plate or cross bar (C) to outlet box (D) with outlet box screws (E)
(not included).
NOTE: For fixtures with an unassembled tail, follow steps 4 and 5. For fixtures with an assem-
bled tail (or no tail) proceed to step 6.
4. Screw center pipe (F) into bottom of fixture cage (H).
5. Slide tail (I), top break (J) and bottom break (K) over center pipe (F). Secure with finial (L).
NOTE: If no tail is desired, remove round nut (G) from bottom of fixture cage (H) and replace
with finial (L).
6. Identify color coding of fixture wires (see figure 2 on page 11).
NOTE: For fixtures employing a grounded convenience outlet: This fixture employs a grounded
type receptacle and is not intended for connection to a two-wire ungrounded source of supply.
7. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against
black outlet box wire. Do not twist wires.
8. Fit wire connector (M from fig. 1) over wires and twist until there is a firm connection.
If wire connector (M) easily comes off, reattach wire connector (M) and check again for
a firm connection (see figure 1).
9. Repeat steps 7 and 8 with the white (group B from fig. 2) fixture wire and outlet box wires.
10. Partially thread green grounding screw (N) into side hole (O) on universal mounting
plate or cross bar (C) (see fig.1).
11. Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box (D)
around green grounding screw (N) on universal mounting plate or cross bar (C).
12. Tighten green grounding screw (N). Do not over tighten.
13. Tuck wires inside outlet box (D).
FIXTURE ASSEMBLY INSTRUCTIONS
1. Place back plate (B) over mounting screws (P) (see fig. 1).
2. Secure into place with cap nuts (A).
3. Remove two inner cap nuts (Q) from top of fixture cage (H).
4. Install lamp(s). Do not exceed recommended wattage.
5. Place fixture cover (R) over fixture cage (H) and secure with inner cap nuts (Q).
6. Turn power back on at circuit box.
4