Reference Designation
REF. :......................................Serial N° :...............................
EXAMPLE
DIA
Type of DOSATRON
Dosage (% or ratio)
RE : Adjustable
F : Fixed
Dosing seals :
AF = PH 7-14
VF = PH 1-7
K = strong acids (>15%)
Other extensions
(consult us)
© DOSATRON INTERNATIONAL / 56
REF. N°: DIA4RE
SERIAL N° : 10400745
4
RE/F
AF
II
Troubleshooting
SYMPTOM
CAUSE
Motor
DOSATRON does
Water not flowing in the
not start or stops.
right direction through
the DOSATRON.
Unit is working, but at
extreme low flow (at
minimum flow 1 click
every 3 minutes!).
Waterflow or -pressure
do not meet or exceed
the unit specifications.
Unit is in bypass mode.
Motor stalled.
Air has not been bled
from unit.
Maximum flow
exceeded.
Wear : Worn actuator
blade spring.
The DOSATRON
Wear : The isolation
does not more start
body and its seal are
at low flow.
worn or dirty.
©
DOSATRON INTERNATIONAL / 57
SOLUTION
Install the unit the
other way around.
Observe the unit for
over 3 minutes. If it
does not click after
this space of time,
check other "causes".
Make certain your
water installation
meets the
DOSATRON waterflow
and pressure
specifications.
Switch « ON ».
1 – Switch « ON »
and « OFF » serveral
times, then switch
« ON ».
2 – Return unit to
your service center for
repair.
Bleed air from unit, by
bleed button.
Reduce flow, restart
unit.
Change the actuator
assembly (PJDI125).
Clean or replace them
(also clean or replace
all injection seals).