Standard double-point calibration
a) Turn on the device, press and hold
b) Press
or
"Line".
c) Press
to make sure that the calibration mode is active.
d) When the scale calibration begins, the digital display shows "Load" and "0.0kg"
alternately.
e) Make sure that there are no objects on the weighing surface. Press
the scale calibration for "0.0kg". During the calibration for "0.0kg" the symbol
"0.0kg" flashes on the display. Assure peace and stability of the weighing surface,
as well as lack of influence of other factors which might disturb weighing. When the
load is maintained in a stable way for longer than 2 seconds, the scale automatically
finishes calibration for "0.0kg" and switches to the next calibration step. Otherwise
the symbol "0.0kg" still flashes on the display until the load is stabilized.
f) The next calibration is displayed automatically, referring to half of the maximum load
(30 or 75 kg). Place the indicated load on the weighing surface, wait until the load
stabilization (flashing stops) and press
g) The scale switches automatically to the calibration of the maximum load (60 or 150 kg).
Place the indicated load on the weighing surface, wait until the load stabilization
(flashing stops) and press
h) Now it is possible to return to the weighing mode.

STOP function

After pressing
seconds after removing the weighed object from the weighing surface. That function
allows for easy load readout.
1. Place the weighed object on the weighing surface.
2. Wait until the displayed value stabilizes.
3. Press
Wait for the acoustic signal. The digital display shows "
.
"STOP".
4.
Remove the weighed object from the weighing surface. The weighed value is shown
on the digital display for 120 seconds.
5.
Exiting/deactivation of STOP function.
The object is weighed and the STOP function is activated. In order to deactivate/exit
the STOP function press
to the weighed value.
- 28 -
to switch to the calibration mode. The digital display shows
to confirm.
key the weighed value is maintained on the digital display for 120
again to turn off "
until the display shows "------".
to confirm.
" symbol meaning STOP and return
to confirm
" indicating