DO NOT REMOVE ANY JUMPER! OTHERWISE THE OPERATOR
CRX
J1
WILL NOT WORK!
AERIAL
Radio Antenna
LSC
Close limit-switch that cuts off the motor in closing
J2
LSO
Open limit-switch that cuts off the motor in opening
COM
Limit-switch common contact
PED BUTT
Pedestrian opening contact (NO)
Main power supply 230 Vac 50/60 Hz (120V/60 Hz upon
J3
L-N
request)
J4
Connection of the earth line
EARTH
J5
RADIO
Built-in radio module (model CRX),
A+ TEST
24 Vdc safety strip self-test power supply
A+
Accessories power supply +24 Vdc
A-
Accessories power supply -24 Vdc
Common contact (common line for all the command and
COM +
safety inputs) (+)
J6
K BUTT.
Single pulse contact (NO)
PHOT.
Photocells contact (NC)
EDGE
Safety strip contact (NC)
Buzzer contact (24 Vdc max 200 mA) (-)
-
Flashing light (max 40 W )
J7
U - MOTOR
Motor common connection
V-W - MOTOR
Motor phase and capacitor connections
Temperature sensor cable connection PROBE (Code
J8
PROBE
ACG4665 optional)
TRIMMER LOW
R1
Electronic regulator for low speed on approach
SPEED
TRIMMER
R2
Electronic torque regulator
TORQUE
RELAYS AND MOTOR COMMAND
K1 => Flashing light command
K2 => Closing command
K3 => Opening command
Q1 => TRIAC - Motor command in opening and closing
POINT B - SETTINGS
DIP 1
(ON) MOTOR ROTATION DIRECTION CHECK (Point C)
DIP 2
(ON) PROGRAMMING (See Point D)
DIP 2-1
PROGRAMMING OF THE PEDESTRIAN OPENING (DIP 2 to ON followed by DIP 1 to ON)
(Point D)
DIP 1-2
STORAGE/DELETION OF RADIO CODES FOR COMPLETE OPENING (DIP 1 to ON followed by
DIP 2 to ON) (POINT F) ONLY FOR CRX MODELS
DIP 1-3
STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN OPENING (DIP 1 to ON followed
by DIP 3 to ON) (POINT G) ONLY FOR CRX MODELS
OPERATING MODE SETTINGS
DIP 3
ON - Automatic Closing ENABLED
DIP 4
ON - Photocells active only in closing
DIP 5
ON - blinker pre-flashing
DIP 6
ON - STEP BY STEP
Single pulse contact (K BUTT) / Pedestrian button (PED BUTT) / Radio Receiver command
DIP 7
ON - electronic brake ENABLED
FOR FAST VERSION code BA03221 - BA03177:
DIP 7
ON - Electronic brake "strong version"
DIP 8
ON - low speed in approaching DISABLED OFF - low speed in approaching ENABLED
DIP 9
ON - gradual start ENABLED
DIP 10
ON - safety strip self-test ENABLED
DIP 11
to select type of motor (see chart 1)
R1
OFF - Automatic Closing DISABLED
OFF - Photocells always active
OFF - blinker normal-flashing
OFF - AUTOMATIC
OFF - electronic brake DISABLED
OFF - Electronic brake "weak version"
OFF - gradual start DISABLED
OFF - safety strip self-test DISABLED
20
R2
J1
DIP 12
to select type of motor (see chart 1)
DIP 11
DIP 12
MOTOR TYPE
OFF
OFF
K800 - K1400 - SUPER 2200
ON
OFF
K5 - K500
OFF
ON
K2200
ON
ON
FREE FOR FUTURE APPLICATIONS
CHART 1 FOR FAST VERSION
DIP 11
DIP 12
MOTOR TYPE
OFF
OFF
SUPER 2200 FAST
ON
OFF
K500 FAST
ON
ON
K800 FAST
OFF
ON
K500 FAST OR FREE FOR FUTURE APPLICATIONS
S1 => PROG. Programming button
TORQUE => R1 Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE Trimmer which varies the output
voltage to the head/s of the motor/s (turn clockwise to increase torque).
This torque control is activated after 2 s form any manoeuvre begging, whereas the motor is
turned on at full power to guarantee the starting at the manoeuvre begging.
IF THE TORQUE TRIMMER SETTING IS CHANGED, IT IS PREFERABLE TO REPEAT THE TIME
PROGRAMMING.
LOW SPEED => R1 Electronic regulator for low speed on approach
J3
J4
J2
J5
CHART 1
J7
J6
J8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ba03227Abk0006Abk0007K-crx 230vK-crx 120v

Tabla de contenido