There are leaks in the vacuum cleaning network
- Check that the ducts are airtight
- Check that the vacuum inlets are not open, distorted or pulled out from the wall
Carry out a duct network test,
with all vacuum inlets closed.
C.Cleaner network test :
Keep pushing button OFF until the maintenance LED lights up in green.
Release button OFF, then press once button OFF then button ON, to make the test begin.
Green : pipework OK / Red = leak
4.3. Fitter's adjustments
Adjusting the start-up sensitivity of the Central Unit:
• Press and hold the OFF button until the maintenance LED lights up in green.
Release the OFF button, then press the ON button to make the maintenance LED flash.
The number of flashes gives the current sensitivity setting on a 1 to 10 scale (the higher the value
the higher the sensitivity).
By default, the sensitivity is adjusted on 5.
• Pressing the ON button increases sensitivity by one step.
Pressing the OFF button decreases sensitivity by one step.
• In order to validate your choice, do not touch the buttons anymore and wait for 30 seconds, letting
the system record the new required parameters.
You now benefit from your new settings.
Synchronisation of the wireless handle with the C.POWER units:
• Keep pushing button OFF until the green LED light for servicing is ON.
Release button OFF then keep pushing the button on the handle until the 3 blue LED lights on the
C.Power unit are on.
The wireless handle is now synchronised with the receiver on the C.Power unit.