Premium PFR4011W Manual De Instrucciones página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

△When defrosting, turn off the power, take out the frozen foods, open the door for
△Do not use sharp metal tools such as steel brush to clean the frost film when
warming and melting. Use soft cloth to absorb water and clean it up.
defrosting so as to avoid evaporator damage.
Trouble shooting
Breakdown
The indicator is not on.
The compressor doses not
start.
The indicator is on ,but the
com- pressor doesn't work and
buzzes only
The
compressor
minute after start, and restart
after a few minutes, and so
repeatedly.
The
compressor
normally,
but the temperature in the
cabinet
lowers too slowly.
The noise is too loud
The following are not faults:
△When the freezer is working or after is stops for a while, the refrigerant in the
△The surface temperature of the compressor may be up 70℃~80℃ when it is
pipes is cycling and gives out"running water"sounds.
△The back side of step freezer gives out heat.
working.
△In rainy season, the outer surface of the cabinet may have dew, which makes no
defects on normal use. Just dry it with a piece of cloth.
The plug isn't connected to the
socket really.
no power
The power voltage is<98V.
stops
a
The power voltage is>132V.
The
door
frequently.
works
The food in the cabinet is too
much, and placed improperly.
The frost film is too thick.
The surface of the condenser is
too dirty.
The door seals badly.
The freezer is placed unstably.
The fixing of the freezer is
loose.
there's contact between pipes.
Case
is
opened
too
Removal method
Replug it.
Connect the socket with
power.
Put a power-regulater more
than
1000W power together.
Reduce open times.
Place foods properly keep
place
between them for ventilation
of
cold air.
Take out foods and defrost.
Stop
and
clean
condenser.
Adjust the door seal.
Place it stably.
Tighten the fixing.
Separate them.
the

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pfr5011wPfr8011w

Tabla de contenido