6. Trouble Shooting
Problem
Possible Cause
No words on the front
Low battery.
LCD panel display.
Battery fault.
The UPS is not turned on.
Alarm continuously
The UPS is overloaded.
sounds although
mains supply is
normal.
When power fails,
The UPS is overloaded.
back-up time is
Battery voltage is too low.
shorten.
Battery defect. Operating
temperature could be too
high, or battery is not
correctly used.
The mains is normal
Power cord is loose.
but the unit is on
battery mode.
7 Specifications
Model
EP 1500
1500 VA / 900 W
CAPACITY
INPUT
Voltage
Voltage Range
OUTPUT
Voltage Regulation
Transfer Time
Waveform
BATTERY
Type & Number
Charging Time
PHYSICAL
Dimension (DxWxH)
Net Weight (kgs)
11.1
Environment
Humidity
0-90 % RH @ 0-40° C (non-condensing)
Noise Level
MANAGEMENT
USB/RS-232
Supports Windows® 98/2000/2003/XP/Vista/2008, Windows®
Solution
Charge the UPS at least 6 hours.
Replace the battery with the same
type of battery.
Press the power switch again to turn
on the UPS.
Remove some devices. Before
reconnecting equipment, please
check that the load matches the UPS
capacity specified in the specs.
Remove some critical load.
Charge the UPS at least 6 hours.
Replace the battery with the same
type of battery.
Check and reconnect the power cord.
EP 2000
2000 VA / 1200 W
110/120 VAC or 220/230/240 VAC
81-145 VAC / 162-290 VAC
+/-10%
Typical 2-6 ms, 10 ms max.
Simulated Sine Wave
12 V/9 AH x 2
4-6 hours recover to 90% capacity
397 x 146 x 205 mm
11.5
Less than 40 dB
7, Linux, and MAC
4
Line Interactive UPS
1. Lieferumfang
Im Lieferumfang sollten Sie folgendes finden:
- USV Einheit
- Kurzanleitung
- Kommunikationskabel (nur für Modelle mit USB/RS-232 Schnittstelle)
- Netzkabel (nur für Modelle mit IEC-Eingang)
2. Produktübersicht
Vorderansicht:
LCD panel
Eingangsspannung
Ausgangsspannung
AC Modus Anzeige
Batterie Modus Anzeige
Ein/Aus Schalter
Rückansicht:
Schuko Typ
NEMA Typ I
Ausgänge
AC Eingang
Schutzschalter
Kurzanleitung V. 1.1
LCD panel:
Lade Status Anzeige, Blinken
zeigt Überladung an
Batteriekapazitätsanzeige, Blinken
zeigt niedrigen Batteriestatus an
NEMA Typ II
IEC Typ
Modem / Telefon / Netzwerk Überspannungsschutz
RS-232 com. Schnittstelle
USB com. Schnittstelle
5
DE