OVERVIEW
6
5
1. Power Switch
Switches the unit on and off, including the USB
charger section (6), the rack light (3 & 4) and the
rear-side power outlets (7). Note that in case the
fuse breaker (2) was tripped, the unit will appear
off even if the power switch is on.
2. Fuse Breaker
10A fuse breaker in series with the power switch,
which will trip if the total power drawn through
the power cord (8) exceeds 10A. If the breaker
is tripped, switch the unit off via the on/off
switch (1), reduce the connected load, press the
actuator on the breaker and power the unit up
again via the power switch (1).
3. LED Light
Downwards-directed LED strip with daylight
colour temperature. Provided this unit is
mounted in the top position of a rack, it can
illuminate the user surfaces of devices mounted
below. The LED light can be switched on and off
and adjusted in its brightness via the dimmer
control (4).
4. LED Light On/Off Switch and Brightness
Control|Turn counter clockwise to reduce
the brightness, and click in the fully counter
clockwise position to switch the LED light (3) off.
Accordingly, turning it clockwise switches on the
LED light and increases the brightness of the LED
light (3).
4
3
5
5. AC Voltmeter.
Displays the current voltage of the AC supply
to which the power cord (8) is connected, in full
volts, with approx. 1% accuracy. This is helpful to
determine whether malfunction of equipment
may be related to AC supply issues.
6. USB charging port.
USB type A socket, 5V DC output with up to 2A of
current.
1
2