7. Switched AC Outlets
Ten IEC 60320 - C13 outlets, which are switched
on and off simultaneously via the power switch
(1). Each single outlet is limited to 5A load,
each group of 5 outlets limited to 8A, while the
total load of all ten outlets together may not
exceed 10A. If the load exceeds 10A, the circuit
breaker (2) will trip. It is NOT recommended to
connect devices such as incandescent lamps,
fog machines or high-power audio amplifiers
to these outlets. The voltage available at these
outlets is filtered for spikes, surges and RF.
8. AC inlet
IEC-C20 power inlet. Make sure to only connect
AC cords to this inlet which can carry the
required power (250V/10A). It is essential that
the outlet to which the power plug is connected
is properly earthed, as otherwise no earthing will
be provided to any devices connected to the
AC outlets (7), which may result in unexpected
performance for equipment which requires
proper earthing.