PROBLEM
The cleaning function stops.
The cleaning function stops and the lights blink
twice every 5 seconds.
The cleaning function stops and the lights blink
twice every 5 seconds.
The cleaning function stops and the lights blink
4 or 5 times every 5 seconds.
The cleaning water is not warm.
The cleaning water is not warm and the lights
blink 6 times every 5 seconds,
The cleaning water is not warm and the lights
blink 7 times every 5 seconds.
The nozzle does not move backwards.
The drying stops or it does not work.
The temperature of the drying air is not warm
enough.
The seat moves when sitting down.
*
Should the problem persist, please call the Technical Assistance.
6. TECHNICAL FEATURES
6.1 FEATURES / SPECIFICATIONS
❚
SPECIFICATIONS
Model
Power supply
Frequency
Max. power input
Heat output
Temperature range
Water pressure
Cleaning
Drying
Length of the connecting cable
24
POSSIBLE CAUSE
The pre-set cleaning time of 2 minutes has ex-
pired.
The infrared sensor has stopped detecting the
user. If the position during use is too forward, the
device might stop detecting the user.
Failure of power supply.
Not enough water is entering the In-Wash. The
shut-off valve is closed or there is a general su-
pply failure.
Not enough water is entering the In-Wash. The
water inlet filter is blocked.
Not enough water is entering the In-Wash. The
inlet flexible hose is pinched or bent.
Not enough water is entering the In_Wash for no
previous reason.
The water outlets of the tip might be blocked due
to limescale or there is a blockage in the water
circuit.
The water has heated up excessively.
The water is adjusted to room temperature.
The water heating tank is not working.
The temperature sensors are not working co-
rrectly.
The power supply has been cut.
The engine of the nozzle has lost its position.
The pre-set drying time of 3 minutes has expired. This is normal. Reactivate the drying function.
The infrared sensor has stopped detecting the
user. If the position during use is too forward, the
device might stop detecting the user.
The temperature of the drying air is set to room
temperature.
The air heater is not working.
The rear brackets of the seat are not tight enou-
gh.
Water heater
Hot air dryer
Service temperature
Water temperature 4 levels
Temperature of the warm air dryer 4 levels
Storage temperature
Flow perineal position
Flow anal position
Safety devices
Air speed of the dryer
Safety device
SOLUTION
This is normal. Activate the cleaning function
again.
Sit down correctly. Reactivate the cleaning func-
*
tion.
Verify the electrical system or unplug and plug in
the cable to the mains.
Verify there is water supply from the mains and
reset the product (See 3.6).
Clean the water filter (See 4.1.3) and reset the
product (See 3.6).
Reposition the inlet flexible hose and reset the
*
product (See 3.6).
*
Descale the tip of the nozzle and reset the pro-
*
duct (See 3.6).
*
Reset the product (See 3.6).
The water is adjusted to room temperature.
*
Reset the product (See 3.6).
*
Reset the product (See 3.6).
Restore the power connection. The nozzle will
move backwards automatically.
*
Reset the product. (See 3.6).
Sit down correctly. Reactivate the cleaning func-
*
tion.
Increase the temperature by means of the remote
control.
*
Tighten the rear brackets of the seat.
In-Wash INSPIRA
220-240V AC
50/60Hz
1700W
1650 W
300 W
10ºC / 30ºC
OFF / 33 / 36 / 39ºC
OFF / 40 / 50 / 60ºC
-10ºC / 60ºC
0,05 Mpa / 0,9 Mpa (0,5 bar - 9 bar)
0,45 – 0,55 – 0,65 l/min
0,65 – 0,75 – 0,85 l/min
Fuse and Thermostat
8,5 m/s
Fuse
1,5 M