valid specifications when shipping li-ion battery
packs. If necessary, consult your freight forwarder.
Certified packaging is available from Metabo.
Only send the battery pack if the housing is intact
and no fluid is leaking. Remove the battery pack
from the machine for sending. Prevent the contacts
from short-circuiting (e.g. by protecting them with
adhesive tape).
5. Overview
See page 2.
1 Front cap
2 Nozzle (for plastic bag) *
3 Tube
4 Threaded ring for fastening the tube
5 Toothed rod
6 Rod knob
7 Trigger switch for switching the device on and
off
8 Adjusting wheel for setting feed rate
9 Battery pack release button
10 Battery pack
11 Plastic bag *
12 Screw
13 Extruder plate for plastic bags
14 Extrusion plate for cartridges
15 Cartridge *
* not included in scope of delivery
6. Initial Operation
6.1
Battery pack
Charge the battery pack before use.
If performance diminishes, recharge the battery
pack.
The ideal storage temperature is between 10°C and
30°C.
To remove the battery pack: Press the battery
pack release button (9) and remove the battery (10)
pack.
To fit the battery pack: Slide in the battery pack
(10) until it engages .
6.2
Fitting plastic bags
Attach the extruder plate for plastic bags
(13) as illustrated. (To do this, (3) unscrew
the tube and then refasten it securely). See page 2,
fig. A.
- Unscrew the front cap (1) from the tube (3).
- Snip the top of the nozzle (2) as required for the
work to be carried out.
- Insert the plastic bag in the tube (3) (thus pushing
back the toothed rod (5)).
- Trim the plastic bag (11) as recommended by the
plastic bag manufacturer.
- Insert the nozzle in the front cap (2) and secure the
front cap (1) tightly.
- Now gently press the rod knob (6) to advance the
toothed rod until it comes in contact with the
plastic bag.
6.3
Fitting the cartridge
Remove the extruder plate for plastic bags
(13) as illustrated. (To do this, (3) unscrew
the tube and then refasten it securely). See page 2,
fig. B.
- Unscrew the front cap (1) from the tube (3).
- Open the cartridge (15) as per the cartridge manu-
facturer's instructions.
- Snip the top of the cartridge nozzle as required for
the work to be carried out.
- Now insert the cartridge (15), with the attached
cartridge nozzle, into the tube (3) (thus pushing
back the rod (5)).
- Screw on the front cap (1) tightly.
- Now gently press the rod knob (6) to advance the
toothed rod until it comes in contact with the
cartridge.
7. Use
7.1
Multifunctional monitoring system
If the device switches off automatically, the
machine electronics have activated automatic
protection mode.
Causes and remedies:
1. Battery pack almost flat (the electronics
prevent the battery pack from discharging totally
and avoid irreparable damage).
If the battery pack is almost flat, it must be
recharged.
2. Long continuous overloading of the machine will
activate the temperature cut-out.
Leave the machine or battery pack to cool.
3. If the current is too high (for example, during
extended periods of overloading) the device is
switched off.
Using the trigger switch, turn off the device (7)
and remove the battery pack. Determine the
cause of the problem and resolve it.
7.2
Setting the feed rate
Set the feed rate using the adjusting wheel (8).
7.3
Switching on and off
Switching on: press the trigger switch (7).
Switching off: release the trigger switch (7). Note:
The toothed rod is automatically retracted slightly to
avoid dripping.
However, if you activate the trigger switch at brief
intervals (shorter than 1 second), the rod is not auto-
matically retracted. This allows precise dosage of
volumes.
Note: The motor switches off automatically if either
the cartridge or the plastic bag is empty.
8. Accessories
Only use original Metabo battery packs and Metabo
accessories.
ENGLISH en
11