CL100
DEFAULT SETTINGS
DIP1
OFF
DIP2
OFF
SETTINGS - dip switch dip2
Dip
Status
DIP1
ON
DIP2
OFF
DIP1
OFF
DIP2
ON
DIP1
ON
DIP2
OFF
DIP1
ON
DIP2
ON
DEFAULT SETTINGS
DIP1
OFF
DIP2
OFF
TRIMMER
Position
Description
Sets the courtesy light enabling time from 1 to 257 s according to the dip switch DIP2 position.
TR1
DEFAULT SETTINGS
TR1 positioned at the minimum
PRODUCT OPERATION
TIMED COURTESY LIGHT MANAGEMENT
1. ENABLING BY FLASHING LIGHT
For the management of a light synchronized to the gate motion, it is necessary to use the flashing light signal in input
(clamps 1 -2 if the flashing light works at 12/24 V; clamps 1-3 if the flashing light works at 230 V) and in output the normally
open contact of the Relay (clamps 9-11)
Following an impulse on the input, the courtesy light output is enabled for the time set with the dip 1 and 2 of the DIP2 and
the trimmer TR1 adjustment.
The courtesy light enabling time starts when the signal is no longer detected on the flashing light input. Continuous
activations of the flashing light input zero the time.
2. ENABLING WITH START SIGNAL
It is possible to enable the courtesy light directly with a START command.
If the START input is configured as bistable, following a START signal the light turns on and remains on until the next
START impulse.
If the START impulse is configured as monostable, the light is enabled following a START command and remains on for
the time set with the trimmer TR1 and the dip switch DIP2.
Function
Description
Courtesy light max t 55 s.
The time can be set with the trimmer TR1.
Courtesy light max t 72 s.
The time can be set with the trimmer TR1.
Courtesy light max t 120 s.
The time can be set with the trimmer TR1.
Courtesy light max t 257 s.
The time can be set with the trimmer TR1.
13