Warnings For The User - GiBiDi CL100 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
12
UK

WARNINGS FOR THE USER

In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service. Any
repairs must be carried out by specialised personnel using original and certified materials.
The appliance is not to be used by children or people with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction.
Do not touch the card for adjustments and/or maintenance.
WARNING: IMPORTANT SAFETY INSTRUCTIONS.
For people's safety, it is important to follow these instructions.
Please keep this manual.
ELECTRICAL CONNECTIONS: FASTONS
Terminal
Position
M1
M2
M3
PROTECTION FUSES
Position
Value
RT1
250 mA
NOTE: The restorable fuse intervenes in case of anomalous operating conditions, breaking the circuit. It is automatically
restored with normal operating conditions so that the card goes back to its correct operation.
If the fuse is not restored automatically, carefully check the devices externally connected to the card.
SETTINGS - dip switch dip1
Dip
Status
DIP1
DIP2
Signal
1
L/S
S12/24
2
L12/24
3
L230
4
+ 12/24
5
- 12/24
6
START
7
LUX
8
COM
9
NO
10
NC
11
COM
12
V_AUX
13
V_AUX
Type
RESTORABLE
Function
ON
12 Vac/dc
OFF
24 Vac/dc
ON
START
OFF
START
Description
Common flashing light/electrical lock
Flashing light or 12/24 electrical lock input
230 V flashing light input
12/24 V power supply card input
12/24 V power supply card input
START input
Photoresistance input
Common START and LUX
NO Contact
NC Contact
Common Contacts
230 V or 12/24 V input for courtesy light or electromagnet
power supply
230 V or 12/24 V input for courtesy light or electromagnet
power supply
Description
Card power supply input protection
Description
Power supply input preset for 12 V
Power supply input preset for 24 V
Bistable START command
Monostable START command
CL100

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

As05200

Tabla de contenido