CL200
Control Unit
Type
Power supply
Operating temperature
PRODUCT DESCRIPTION
The electronic card AS05530 allows the functioning of the led signalling lights and the management of the obstacle
detection device on the GBD rising bollards.
TECHNICAL SPECIFICATIONS / FUNCTIONS
• Input for lights functioning synchronized with and complementary to the WARNING LIGHT signal from the control unit.
• Input for detection device management.
• Output for emergency signalling to the control unit.
• Possibility to connect the power supply output of the control unit to perform the card test.
INSTALLATION WARNINGS
• Before starting the installation, fit a magnetothermal or differential switch with a maximum capacity of 10A upstream of
the system. The switch must guarantee omnipolar separation of the contacts, with an opening distance of at least
3 mm.
• To prevent possible interference, differentiate and always keep the power cables (minimum cross-section 1,5 mm²)
separate from the signal cables (minimum cross-section 0,5 mm²).
• Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to
connect in series all the devices that must be connected to the same N.C. (normally closed) input, and in parallel all
the devices that share the same N.O. (normally open) input. Incorrect installation or improper use of the product may
compromise system safety.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific automation are not used.
• At the end of the installation, always check carefully the proper functioning of the system and the devices used.
• This instruction manual addresses people qualified for the installation of "live equipment". Therefore, good technical
knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed. Check the aim of the final use and make
sure that all safety measures are taken.
• Use of the product for purposes different from the intended use has not been tested by the manufacturer, therefore
any work is carried out on full responsibility of the installer.
AS05530 - CL200
Interface card for light management and obstacle detection device
management for rising bollards
24 Vac-dc
-20°C +60°C
5
UK