Mounting And Connections - Allmatic KAIROS Manual De Instrucciones

Ocultar thumbs Ver también para KAIROS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. MOUNTING AND CONNECTIONS

Mounting instructions:
• Attach the plate 1 to the wall using the drilling table (see Chap-
ter 9) at least 2m from the ground.
• Apply the gasket 2 , passing the power cable through the hole
(only on standard versions).
• Connect the power cable to the terminal 3 (only on standard
versions).
• Screw 4 the sensor to the wall plate, lift the sensor and screw
the screws 5 .
• Remove the protection 6 and adjust the grade of the sensor so
that the blades are level (see below).
• Tighten the screw with a hexagonal wrench of 4 and reposition
the protection 6 by inserting it from the bottom and pressing
until closing.
• Cover with the covers 7 .
120°
7
4
5
2
3
WARNING!
If you are using a KAIROS sensor with solar panel power it is very important to ensure that it is installed in a position
that is exposed as much as possible to direct sunlight.
In case the sensor is covered or shadowed by buildings or trees, the photovoltaic panel does not properly supply the
sensor and therefore the buffer battery inside the sensor can be consumed early making the device stop working.
For replacement of the buffer battery refer to chapter "6. MAINTENANCE".
6 / 12
INDICATIONS OF INSTALLATION
6
5
1
2
3
6
ENG
7
4
6
N
W
E
S
6-1622652 - rev.4 - 20/05/2021

Publicidad

Tabla de contenido
loading

Tabla de contenido