Change Of Sensor Identification Code (Id); Troubleshooting (Faq) - Allmatic KAIROS Manual De Instrucciones

Ocultar thumbs Ver también para KAIROS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. CHANGE OF SENSOR IDENTIFICATION CODE (ID)

To be performed only in exceptional cases.
The ID change is necessary when two sensors operate in the same range and have the same ID; this operation allows you to auto-
matically change the ID.
Press and hold the A button for more than 20 seconds.
The LED starts flashing red, yellow, amber, and when the LED turns on green fixed the ID change was executed correctly and you
can release the key.
Releasing the key before the end of the procedure cancels the ID change.
ATTENTION!
After the ID change, repeat the procedure for learning the sensor on the control unit.

8. TROUBLESHOOTING (FAQ)

Trouble
When the sensor A button is
pressed, the LED does not flash.
The automation does not close in
case of wind.
The automation closes with little
wind.
Automation opens too late in the
morning.
Automation opens too early in the
morning.
Automation always has an active
rain alarm.
10 / 12
Possible causes
Lack of power.
The set threshold (trimmer) of the
wind sensor is too high.
Wrong incline of the sensor.
Wrong settings of the control unit.
The set threshold (trimmer) of the
wind sensor is too low.
The threshold set (trimmer) of the
light sensor is too high.
The threshold set (trimmer) of the
light sensor is too low.
The set threshold (trimmer) of the
rain sensor is too low.
ENG
Solutions
Standard versions:
Check power supply connection.
"Stand-Alone" versions:
Clean the photovoltaic panel surface and
leave the sensor in direct sunlight for at
least 10-15 minutes.
Replace the buffer battery, inside the
sensor.
Rotate the trimmer adjusting the wind sensor
counterclockwise to a lower value.
Adjust the grade of the sensor so that the wind
sensor blades are level.
Check the Control Unit settings.
Rotate the trimmer adjusting the wind sensor
clockwise over a higher value.
Rotate the light adjusting trimmer counter-
clockwise to a lower value.
It is recommended to use the ADJUSTMENT
MODE for this adjustment.
Rotate the light adjusting trimmer clockwise
over a higher value.
It is recommended to use the ADJUSTMENT
MODE for this adjustment.
Check that the adjustment trimmer is not set
to the "Test" position and adjust the trimmer
clockwise over a higher value.
It is recommended to use the ADJUSTMENT
MODE for this adjustment.
6-1622652 - rev.4 - 20/05/2021