Characteristics
• for gradual switching of heavy wads (for example electrical heating), prevents
current strokes in the main
• function: 2x Delay ON (2 time relays in one)
• time scale 0.1s - 10 days divided into 10 time ranges:
0.1s - 1s / 1s - 10s / 0.1min - 1min / 1min - 10min / 0.1h - 1h / 1h - 10hrs / 0.1 day -
1 day / 1 day - 10 days / ON / OFF
• times t1 and t2 are independantly adjustable
• t1 and t2 are switched on after supply voltage connection
• rought time setting via rotary switch
• supply voltage: AC 230 V or AC/DC 12 - 240 V
• output contact: 2x changeover / DPDT 16 A
• output indication: multifunction red LED, fl ashing at certain states
• 1-MODULE, DIN rail mounting
Description
3
4
5
6
7
cos φ ≥ 0.95
Type of load
AC1
Mat. contacts AgNi,
contact 16 A
250V / 16A
Type of load
AC13
Mat. contacts AgNi,
contact 16 A
250V / 6A
1. Supply voltage terminals
1
2. Output indication
3. Supply voltage indication
2
4. Rought time setting t1
5. Fine time setting t1
6. Rought time setting t2
7. Fine time setting t2
8. Output contact
8
8
M
M
AC2
AC3
uncompensated
250V / 5A
250V / 3A
230V / 3A (690VA)
K
AC14
AC15
250V / 6A
250V / 6A
24V / 16A
SJR-2
Doublestage delay unit
Symbol
Connection
AC5a
AC5a
compensated
AC5b
x
800W
M
DC3
DC1
DC5
24V / 6A
24V / 4A
1 / 2
A1
16
18
26 28
A2
15
25
Un
A1
A2
25 26 28
15 16 18
HAL.230V
AC6a
AC7b
x
250V / 3A
M
DC12
DC13
24V / 16A
24V / 2A
EN
AC12
250V / 10A
DC14
24V / 2A