Descargar Imprimir esta página

Elko EP DCFR-1 Manual De Instrucciones página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: elko@elkoep.com
www.elkoep.com
Made in Czech Republic
02-188/2016 Rev.: 0
Characteristics
• universal DCF module, intended to control time switch SHT-6, or other devices
• suitable for outdoor use (IP65 protection)
• two wire connection - not depends on polarity!
• cable lengths of up to 100 meters
• optical indication of proper module function
Description
connection
with SHT-6
(max. 100 m)
Connection with SHT-6
N
A1 G B1 B2
SHT-6
A2 16 15 18
L
In case of using shielded cable it is necessary to connect the shield to terminal G.
Technical parameters
Connection:
Max. conductor cross-section:
Max. voltage on the wires:
Indicator functions:
Other information
Storage temperature:
Protection degree:
Dimensions:
Weight:
Operating position:
Service area:
LED
DCFR-1
DCFR-1
2 conductors
2
2.5 mm
10 V
red LED
-30.. +70 °C (-22.. 158 °F)
IP65
98 x 62 x 34 mm (3.85" x 2.44" x 1.34")
110 g (3.88 oz)
perpendicular to the direction of reception
about 1500 km from Frankfurt / Main
DCFR-1
Receiver DCF 77
Installation
For mounting DCFR-1 is necessary
to choose an appropriate place in
the open air, best on the façade
or under the roof, remember
to maintain the right direction
regardless of signal reception.
DCFR-1 needs to be installed as
far as possible from the following
devices (at least 3 m):
- metal construction
- electrical switchboards
- TV receivers, monitors, laptops
- radio broadcasting and other
similar devices
WARNING: DCFR-1 is electrically
connected to the power supply
circuits SHT-6 - it is necessary
to provide adequate insulation
coverage when installing the
service cable.
Function
DCFR-1 is designed to receive and decode the signal DCF-77. The correct operation is
indicated by the red LED fl ashing at interval 1s.
Warning
Installation and connection should only be carried out by a qualifi ed installer or
electrician, who is thoroughly familiar with these instructions and functions of device.
Before starting the installation, please make sure that the device is de-energized and
the main switch is in the off position. For installation and setting use screw-driver cca
2 mm. The device is fully-electronic - installation should be carried out according to this
fact. Non-problematic function depends also on the way of transportation, storing and
handling. In case of any signs of destruction, deformation, non-function or missing part,
don´t install and claim at your seller it is possible to dismount the device after its lifetime,
recycle, or store in protective dump.
1 / 1