SEA 23102076 Manual De Instrucciones página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
GB
INFRARED BEAM PHOTOCELL SUNSET
General
The photoelectric barrier SUNSET has been projected for applications in which it is necessary to apply two
overlapping photocells, avoiding that they go in collision one with the other. To get such result it is sufficiant to
power supply the photocells with 12/24 V~ and to cross the power supply. (Ex. When the TX and RX of a
photocell are power supplied with a black cable around 0 V~ and with a red cable of 24V~, the TX and the RX
of the other photocell will have to have the red cable with 0 V~ and the black cable around 24 V~.)
The Photocell Kit Consists of:
1 No. Photocell Receiver
1 No. Photocell Transmitter
1 No. Fixing Kit
2 No. cover-screw cap
1 No. Set of fitting instructions
Technical Characteristics
Range:
Signal:
Wave length:
Modulation Frequency:
Supply Voltage:
Absorbed Current:
Temp. Operating Range:
Relay Contact Rating:
Humidity:
INSTALLATION
Transmitter
-Insert the cables in the special seat and make the connections
according to the type of application, 12 or 24V~ or V
synchronized or not synchronized.
-Adjust the cable within the unit to eliminate any surplus.
-Fix the unit.
-Seal the cover & cable entry to prevent insect infestation.
Receiver
-Insert the cables into the special seat and make the connections
accoriding to the type of application chosen for the transmitter, 12/
24V~ or V
, synchronized or not synchronized.
-Adjust the cable within the unit to eliminate any surplus.
-Make sure that the receiver is in frontal position, lined up on the
same axis and in the same height of the associated transmitter.
-Seal the cover & cable entry to prevent insect infestation.
Once executed the preceding operations for both Tx and for Rx:
-Power supply the photocells 12-24V~ or V
alignment. If the positioning, the alignment and the connection of
the photocells are correct, the red LED on the receiver will be
switched on.
Please note: For the syncronized function, the power supply has to be necessarily of 12/24 V~.
Cod. 67410885
®
SEA S.r.l.
DIREZIONE E STABILIMENTO:
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. 0861 588341 r.a. Fax 0861 588344
(cod. 23102076)
15 m (exterior use)
Modulated infrared
880 nm
1000 Hz
12 - 24 V
30mA TX; 30mA RX
-15° C / +60° C
1A max; 24V
from 5% to 90% no
condensation
English
/ V~
,
and verify their
Rev. 03 - 09/2009
http://www.seateam.com
e-mail:seacom@seateam.com
42
JP1
JP1
Fig. 1
Tx1
1
1
2 3
0 0
+12
+12
+24
+24
0 0
+12
+12
42
JP1
JP1
Fig. 1
Tx2
1
1
2 3
0 0
+12
+12
+24
+24
0 0
JP1 ON = SYNCRONIZATION ACTIVATED
JP1 OFF = SYNCRONIZATION NOT ACTIVATED
Fig.2
42
JP1
JP1
Rx1
2
3
4
5 6
+24
+24
42
JP1
JP1
Rx2
2
3
4
5 6
+12
+12
+24
+24
21 mm
30 mm
Pag. 1

Publicidad

Tabla de contenido
loading

Tabla de contenido