• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions in this manual.
• Identify the specific appliance model. The model number is
detailed on the packaging and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.
• The appliance must be used in non-saline environments with
max. humidity 75%, with a temperature of between +5°C
(41°F) and + 35°C (95°F) and in any case in an environment
that does not cause any malfunction of the device.

5 REFERENCE STANDARDS AND LAWS

Install the appliance in conformity to current statutory safety
standards.
Install the appliance in compliance with the prescriptions of
EN1717 and the water pollution regulations in force in your
country.

6 UNPACKING

Check the state of the packaging and in the event of damage,
ask the delivery person to inspect the goods.
• Remove the packaging.
• Remove the protective film from the external panels. Use a
suitable solvent to remove any residual adhesive from the
panels.

7 POSITIONING

• The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the start
of this manual.
• The appliance can be installed independently.
• Position the appliance at least 10 cm from adjacent walls.
This distance can be reduced in the presence of non-combu-
stible walls or heat-insulated walls.
• The appliance is not suitable for flush mounting.
• The appliance must be placed on a dry, smooth, strong, sta-
ble and even surface of a sufficient width, at least 80 cm from
the ground.

8 FUMES EXHAUST SYSTEM

Create a fumes exhaust system based on the "Type" of ap-
pliance.The "Type" is stated on the appliance data plate.
8.1 APPLIANCE TYPE "A1"
• Position the "A1" type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are removed
8.2 APPLIANCE TYPE "B21"
• Position the "B21" type appliance below an extractor hood
8.3 APPLIANCE TYPE "B11"
• Fit the "B11" type appliance with a suitable flue, available
from the appliance manufacturer Follow the assembly in-
structions provided with the flue.
• Connect the flue to a 150/155 mm diameter hose, heat resi-
stant to 300°C.
• Vent to the outside or into an efficient flue. The hose length
must not exceed 3 metres.

9 CONNECTIONS

The position and dimensions of connections are given in the
installation diagram at the start of this manual.
9.1 CONNECTION TO THE GAS SUPPLY
Check the compatibility of the gas supply. Check the details
given on the decals on the packing and on the appliance.Con-
vert the appliance to the local gas type, if necessary. Follow the
instructions in the next paragraph "Conversion to a different
type of gas".
On top appliances a rear connection is also available. Remove
the plug present and screw it tightly onto the front connector.
• A rapid-action gas shut-off valve must be fitted upstream of
the appliance in an easily accessible position.
• Do not use connection pipes having a diameter smaller than
that of the appliance's gas connector.
• Once the appliance has been installed, check for gas leaks at
the connection points.

10 CONVERSION TO A DIFFERENT TYPE OF GAS

Table T1 specifies, for each country:
• which gas can be used for the appliance
• the nozzles and settings foreach gas that can be usedFor
nozzles, the number indicated in table T1 is also stamped on
the nozzle body.
To convert the appliance to the local gas type, follow the in-
structions given in atable T1 and carry out the steps below:
• Replace the main burner nozzle ( UM ).
• Adjust the main burner's air regulator to distance A.
• Replace the pilot burner nozzle ( UP ).
• Adjust the pilot burner air flow (if necessary).
• Replace the gas valve minimum nozzle ( Um ).
• Affix the adhesive tab indicating the new type of gas used.The
nozzles and adhesive tabs are supplied with the appliance.
10.1 REPLACING THE MAIN BURNER NOZZLE AND ADJU-
STING THE PRIMARY AIR FLOW
• Remove the control panel.
• Remove the grilles, tiles and burners.
• Remove nozzle UM and replace it with the one indicated in
table T1.
• Retighten nozzle UM.
• Slacken screw V and position the air regulator at distance A
as indicated in table T1.
• Retighten screw V fully.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
10.2 REPLACING THE MINIMUM ADJUSTMENT SCREW
• Remove the control panel.
• Remove nozzle UM and replace it with the one indicated in
table T1.
• Retighten nozzle UM.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
10.3 REPLACING THE PILOT BURNER NOZZLE
• Remove the control panel.
• Unscrew plug T.
• Remove nozzle UP and replace it with the one indicated in
table T1.
• Retighten the plug T. Re-assemble all parts.
• For assembly, proceed in reverse order.