XT SIMPLE Combi Direct 5 x 2/3 GN / 5-10-15 x 1/1 GN / 5-10 x (60x40)
VAR-03
INSTRUCTIONS FOR THE INSTALLATION
ENGLISH
2.4-PLUMBING – WATER DRAINAGE
Drainage for the water is at the back of the oven and
must be connected directly to the end of the stainless
steel drainpipe.
The drain must have no trap and be made in rigid pipes
that can withstand a temperature of 110°C.
Under no circumstances must pipe diameter be reduced.
The actual pipe should be at atmospheric pressure with
the appropriate funnel type air intake.
If the drainpipe is clogged for any reason steam can
escape from the door and bad smells can be created
inside in the oven.
Important:
The drain system must be installed so that
any vapours coming from the open drain do not enter the
aeration vents under the appliance. (Fig. 2.4 and 2.4A).
< 30 cm
> 50 cm
Fig. 2.4
Fig. 2.4A
30