2. Slowly fill the discharge tee with water until
water overflows the vent plug opening.
Replace the vent plug loosely.
NOTE: It will take several minutes to fill pump/
tank (A) and suction pipe completely.
3. Be sure entire suction pipe is filled when
priming. Depending on the length of suction
pipe, many gallons will be needed to fill the
entire system.
4. Check to be sure water in the cavity of pump/
tank (A) stays constant. If water level goes
down, it could indicate a leak in the foot
valve, check valve or suction pipe.
2
Suction pipe
3
Suction pipe
4
Suction pipe
14
Vent plug
Priming plug
opening
opening
Vent plug
Discharge Tee
A
Water Level
Check for leaks
A