Descargar Imprimir esta página

Truma LevelCheck Manual Del Usuario página 5

Indicador de contenido ebombonas de gas
Ocultar thumbs Ver también para LevelCheck:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
The status LED (3) flashes orange during the
measuring process.
The end of the measurement is indicated via a
second beeping tone and the measuring result is
displayed on the status LED (3).
Status LED green – Liquid detected at the
measuring point
Status LED red
– No liquid or inaccurate
measurement
The device switches off automatically after a
measurement has been taken.
LED light
The LED light (2) is switched on by pressing the
button (4). Re-pressing the button switches the
LED light off again. The LED light switches off au-
tomatically after around 5 minutes.
Undervoltage / malfunction
− The displayed measuring result flashes: The
battery is low (measurements can still be taken)
− The red status LED flashes and beeps 3 times:
The battery is empty (measurements can no
longer be taken)
90°
Battery change
Please only use leak-resistant batteries
(E-Block 9 V), Type 6 LR 61, 6 F 22.
Unscrew the screw (7) from the lower shell. Push
the lower shell in the direction of the arrow and
detach. Replace the battery and when doing so,
check the polarity of the wires.
Dispose of the empty battery correctly and sepa-
rately from the device.
An empty spent battery can leak and dam-
age the device! Remove the battery from
the device if the device is not going to be used for
a longer period.
The warranty will not apply to damage caused by
leaking batteries.
Disposal
Dispose of the device and the battery sepa-
rately in accordance with the administrative
regulations of the respective country.
National regulations and laws must be observed.
Technical data
Power supply
Dimensions (W x H x D)
Weight (incl. battery)
The right to effect technical modifications is
reserved!
E-Block 9 V
138 x 35 x 30 mm
approx. 100 g
5

Publicidad

loading

Productos relacionados para Truma LevelCheck