Input, output and audio controls
ventilation
1. INPUT:
Input of the signal to be amplified. Connect to the radio/player
through high quality shielded RCA cables to prevent unwanted noise.
2. LEVEL:
Signal level control in the amplifier input.
3. CROSSOVER:
HIGH PASS FILTER (H.P.F.):
▪
frequency from 10Hz to 90Hz that will be reproduced by the amplifier.
LOW PASS FILTER (L.P.F.):
▪
frequency from 90Hz to 22KHz that will be reproduced by amplifier.
4. BASS BOOST:
Variable control for bass boost from 0dB to +10dB.
BASS:
▪
Variable control for BASS boost action from 30Hz to 70Hz.
FREQ:
▪
4.1. MID BASS BOOST:
4.2 MID HIGH BOOST:
boosting midrange at 2KHz frequency.
5. FLAT KEY:
This switch allows you to turn the FLAT mode on or off. Settings made
on the CROSSOVER and BOOST controls will be turned off when using this mode.
6. OUTPUT CONNECTOR (SPEAKERS):
speakers connection. Check the minimum impedance and polarities before
performing the installation.
1
2
3
This variable control allows you to select the initial
This variable control allows you to select the final
Variable control from 0dB to +10dB with bass boost at 270Hz.
Variable control from 0dB to +10dB with acting on
4
4.1 4.2
5
MONO output of amplified signal for
12
ventilation
6