Descargar Imprimir esta página

GEV CAS 87408 Manual Del Usuario página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
CAS door intercom for 1 to 6 apartments
Operating elements
Connection elements
Indoor monitor (fi g. A)
Indoor monitor (fi g. C) 1 to 6
1 Microphone
1 Power supply connector
2 Volume adjustment
2 Power supply terminal
3 Loudspeaker
3 Outdoor monitor connection
4 Talk button
4 Outdoor monitor connection
5 Outdoor monitor/Cut off
5 Floating relay contact
connection
(Normally Open)
6 Open door button
6 Floating relay contact
7 LED status indicator
(Normally Open)
8 ON/OFF switch
7 Outdoor bell
9 Ring tone selection/OFF
8 Outdoor bell
10 Ring tone volume adjustment
9 Storey bell
10 Storey bell
11 Additional indoor monitor
Outdoor monitor (fi g. B) 1 to 6
1 Loudspeaker
Outdoor monitor (Fig. D)
2 Bell (1 to 6)
3 Label (1 to 6)
Door opener relay positive connector (+)
4 Microphone
Door opener relay negative connector (-)
5 Volume adjustment (at rear)
1 Indoor monitor 1 connection <> C3
1
2 Indoor monitor 1 connection <> C4
Power pack (fi g. E) 1 to 6
1 Indoor monitor 2 connection <> C3
2
2 Indoor monitor 2 connection <> C4
1 Plug
1 Indoor monitor 3 connection <> C3
3
2 Indoor monitor 3 connection <> C4
1 Indoor monitor 4 connection <> C3
4
2 Indoor monitor 4 connection <> C4
1 Indoor monitor 5 connection <> C3
5
2 Indoor monitor 5 connection <> C4
1 Indoor monitor 6 connection <> C3
6
2 Indoor monitor 6 connection <> C4
Safety information
All warranty claims will be null and void in the event of any
damage or loss caused by failure to observe these operating
instructions. We accept no liability for any consequential losses
or damage. We accept no liability for any personal injury or
material damage caused by improper use or by failure to observe the
safety advice. In these cases the guarantee and warranty are invalidated.
For safety and authorisation purposes it is not permitted to carry out any
adaptation or conversion of the device.
Installation
If in any doubt, rather than mounting, connecting or installing the
equipment yourself, contact a qualifi ed technician.
When deciding where to install the outdoor monitor, choose a position that
is well protected against the elements, particularly rain. If necessary, use
waterproof housing to protect the device. The device must be positioned
so that the microphone (B4) is at the bottom.
Remove the cover (fi g. F1) and install the outdoor monitor according to
fi g. F2. Fit the seal so that the open ends face downwards. Carefully
remove the cover (fi g. F3) to write on the labels.
Install the indoor monitor according to fi g. G.
Connection
Connect the door intercom according to fi g. H.
Connection accessories: see additional sheet.
Power supply
All indoor monitors must have their own power supply. Connect E1
power pack plug to socket C1. Alternatively, use a central power
supply system (not supplied) and connect it to plug-in terminal C2 (making
sure that you connect it correctly). If using a central power supply system,
observe the minimum power requirements (see Technical Data).
For
a
central
power
supply
system,
only
short- circuit-proof power supply units are authorised. Only
allow voltages/voltage types specifi ed in the "Technical Data"
section, with due regard for the required minimum current.
Allowing other voltages or voltage types will destroy the door intercom.
Make sure that the cables are correctly connected. Incorrect cable
connection will also destroy the door intercom.
Door opener
An electric door opener can be directly connected to the CAS door inter-
com. Supply voltage: 12 V DC/max. 1 A.
Caution: do not use door openers requiring a higher operating current, as
this is likely to damage your CAS door intercom (and render your warranty
null and void).
Operation
Set ON/OFF switch A8 to ON. The LED A7 lights up green and the B3 label
on the outdoor monitor also lights up. The device is now ready for use.
Use switch A9 to select the required ring tone (1 to 3) or disable the ring
tone (0 = OFF). If the ring tone is disabled, the LED A7 will light up red. Use
volume adjustment A10 to set the ring tone volume independently of the
general volume. Use volume adjustment A2 to set the general volume. Use
volume adjustment B5 to set the outdoor monitor volume.
If a visitor presses bell B2, the indoor monitor and (where fi tted) the
external bell or additional indoor monitor will ring. The visitor can then
speak into the outside monitor and be heard by the person inside the
building. At this point, the person inside the building cannot be heard by
the person outside the building. Button A5 lights up when connection from
the outdoor to the indoor monitor is enabled. If no buttons are pressed,
connection will stop automatically after approx. 30 seconds.
If talk button A4 is pressed, the person inside the building can
communicate with the person outside the building. In this case, talk button
A4 will light up. Press the door open button A6 to activate the (optional)
door opener.
Press button A4 or A5 again to stop communication. If no buttons are
pressed, communication will be automatically interrupted after approx.
2 minutes
Outside monitoring
Press
button
A5
to
monitor
the
respective
outside
30 seconds.
Extending the system
Storey bell (optional)
Connect a standard button to connecting elements C9/C10. If this button
is pressed, the indoor monitor will ring with a preset ring tone. (This ring
tone cannot be adjusted.)
Outdoor bell (optional)
The CAS outdoor bell (item no. 087613) can be connected to connecting
elements C7/C8. The bell features volume adjustment with 3 volume
settings: OFF/quiet/loud.
Wireless bell (optional)
Terminals C5/C6 feature a fl oating relay contact (Normally Open). This
contact is closed for 1 second when bell B2 is pressed. For example,
connect the GEV CGF 7079 wireless bell. Connect C5/C6 to contacts
1 + 3 on the CGF 7079 wireless bell.
Additional indoor monitor (optional) CAS 087682
Connect an additional indoor monitor using connector C11. Connection takes
place via a (6 wire shielded) cable featuring an RJ12 plug. The additional monitor
features connections for an outdoor bell or the CGF 7079 wireless bell.
4
Connecting a handset (optional)
For more privacy, you can connect a handset to the indoor monitor.
Connect the handset according to additional sheet and secure. Simply lift
GS-tested,
up the handset to communicate with the person who has just pressed bell
B2. The loudspeaker is automatically disabled when the handset is lifted
up. Press the talk button at any time to conduct a conversation via the
loudspeaker and microphone.
CE compliance information
Using the device near electromagnetic high frequency fi elds such as radio
systems, microwaves or mobile phones, or high electrostatic discharge,
can interfere with device operation. Should you encounter problems,
switch the power supply off and on again to restore operation.
Troubleshooting - Practical tips
Problem
No ring tone, LED does not light up
No ring tone, LED lights up green
No ring tone, LED lights up red
Door opener does not work
Technical data
Indoor/additional monitor dimensions
Outdoor monitor
for 1 or 2 apartments
3 apartments
4 apartments
5 apartments
6 apartments
Power supply
Indoor monitor power supply (without door opener)
Standby mode
Operating mode
Connection
Distance from indoor to outdoor monitor
Distance from indoor monitor to additional monitor
area
for
Distance from indoor/additional monitor to bell
Power pack (for each indoor monitor)
Input voltage
Output voltage
Rated current
Central power supply
Power supply
Rated current for 1 apartment
Rated current for 2 apartments
Rated current for 3 apartments
Rated current for 4 apartments
Rated current for 5 apartments
Rated current for 6 apartments
We reserve the right to make technical and visual modifi cations without prior notice.
Gutkes GmbH
Rehkamp 13
Fax: +49 (0)511/95 85 805
30853 Langenhagen
www.gev.de
Germany
service@gev.de
Recycling instructions
This device may not be disposed of with unsorted household waste.
Owners of old devices are required by law to dispose of this device
correctly. Contact your local town council for further information.
Cause
Solution
Is the power pack connected?
Connect/check the power pack
Is the power pack faulty?
Faulty device?
Check the device
Is the cable connecting the indoor and
Check the cable
outdoor monitor incorrectly connected/faulty?
Is the ring tone volume adjustment set to 0?
Set ring tone adjustment to 1, 2 or 3
Wrong type of door opener?
Use a 12 V DC max. door opener
approx. W 85 x H 200 x D 40 mm
approx. W 81 x H 152 x D 47 mm
approx. W 81 x H 173 x D 47 mm
approx. W 81 x H 194 x D 47 mm
approx. W 81 x H 215 x D 47 mm
approx. W 81 x H 236 x D 47 mm
15 V
approx. 1 W
approx. 6 W
12 V
/max. 1 A
2
70 m max. (0.75 mm
)
2
20 m max. (0.45 mm
)
2
20 m max. (0.45 mm
)
100-240V, 50/60Hz
15 V
max. 1 A
15 V
max. 1.0 A
max. 1.1 A
max. 1.2 A
max. 1.3 A
max. 1.4 A
max. 1. 5 A
5