10. Troubleshooting

Troubles
1.Unit does not start when pres-
sing on/off button.
2. Not cool enough.
3. Noisy.
4. E0 Code.
5. E1 Code.
6. E2 Code.
7. E3 Code.
8. UV light does not activate.
Note: The real products may look different.
Possible Causes
- Water full indicator lamp blinks,
and water tank is full.
- Room temperature is lower
than the setting temperature.
- The doors or airows are not
closed.
- There are heat sources inside
the room.
- Exhaust air hose is not connec-
ted or blocked.
- Temperature setting is too high.
- Air inlet is blocked.
- The ground is not level or not
flat enough.
- The sound comes from the
flowing of the refrigerant inside
the air conditioner.
Room temperature sensor failed.
Condenser temperature sensor
failed.
Water tank full when cooling.
Evaporator temperature sensor
failed.
UV light does not work.
33
Suggested Remedies
Dump the water out of the water
tank.
Reset the temperature.
Make sure all the airows and
doors are closed.
Remove the heat sources if
possible.
Connect or clean the exhaust air
hose.
Reset the temperature.
Clean the air inlet.
Place the unit on a flat, level
ground if possible.
It is normal.
Replace room temperature
sensor (the unit can also work
without replacement).
Replace condenser temperature
sensor.
Take off rubber stopper and
empty the water.
Replace evaporator temperature
sensor.
Replace the lamp. Send an email
to info@evsa.net.