ELECTRICAL CONNECTION OF YOUR HOB

· Before proceeding with the electrical connection, verify that the current
carrying capacity of the system and the socket is adequate for the maximum
power rating of the hob.
· Electrical installation of the residence and the electrical current plug in
use must be earthed and conform with safety regulations.
· If there is no dedicated hob circuit and fused switch, they must be installed
by a qualified electrician before the hob is connected.
. Fused switch must be easily accessible once the hob has been installed.
· Do not use adaptors, multiple sockets and/or extension leads.
· This appliance conforms with the requirements ofthe following EEC
Directives:
1. Vitroceramic hob EEC/73/23 and 93/68, EEC/89/336 relating to
radio interference,
2. EEC/89/109 relating to contact with foods.
· A circuit breaker with a contact opening of at least 3mm, rated 20A and
delayed functioning type must be installed inside the supply circuit.
· For the vitroceramic hob, the cable must be H05VV-F 5X1,5mm² for 3
phase or 3X1,5mm² for single phase / 60227 IEC 53. You will find the
connection diagram shown on the bottom of your appliance.
L
3X1.5mm² H05V V-F
type power supply cord must be used.
Grounding lead must be connected
to screw with
8
N
symbol.