Initial Start-Up; Electrical Connection; Start- Up Sequence - Ingersoll Rand Nirvana NVC2000 A400 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

AIR IN
UNIT AS DELIVERED
OPTIONAL ACCESSORY ITEMS
NOTE:
8.4

ELECTRICAL CONNECTION

Equipment is available in various electrical configurations. All customer
connections can be made at the terminal connections located in the
customer electrical connection box on the rear of the dryer. (Refer to
General Arrangement and appropriate Wiring Diagrams.)
A suitable fused disconnect switch or circuit breaker, in accordance with
national and local code requirements, is recommended for all Ingersoll
Rand equipment. Refer to the Engineering Specifications Section for
voltage requirements and load.
A
CAUTION
Never wire directly or connect any additional wires to the compressor
junction box. This will cause severe system malfunction.
8.4.1
Ingersoll Rand dryers can be configured for three variations of
start modes: Manual Mode, Automatic Mode and Remote
Mode. Refer to Section 10 for instructions on how to change
the dryer's start settings. The instructions below describe the
methods to configure the dryer for a particular Start Mode.
A) Manual Mode (Factory Default) - No modification required
to operate dryer in Manual Mode. Once power is applied,
dryer can be started or stopped by depressing the local
ON / OFF pushbuttons located on the front panel.
B) Auto Restart Mode - Auto Restart Mode permits the dryer
to start after a brief delay once power is applied to the
dryer. Note that the dryer's touch pad will still affect dryer
operation. Depressing the OFF button will de-energize the
refrigeration
compressor
components. After the OFF button has been depressed,
the user must depress the ON button to permit the dryer to
operate.
10
8.0 INSTALLATION AND INITIAL START-UP
B
PRE-FILTER
PREFILTER
DRAIN
VALVE
CHECK
CHECK
VALVE
VALVE
DRAIN TUBE MUST NOT RISE OR BE CONNECTED TO
EXCESSIVELY LONG PIPE WHICH MAY CREATE BACK PRESSURE
A CONNECTION TO OPEN FLOOR DRAIN IS REQUIRED
TYPICAL PIPING ARRANGEMENT
and
all
other
electrical
Nirvana Cycling Refrigerated Dryer Models 2000-2400
A
AIR
DRYER
C
E
D
CHECK
CHECK
VALVE
FIGURE 3
C) Remote Mode - Remote Mode allows the dryer to be
turned ON or OFF via a remote switch supplied by the
customer. This mode will work regardless of the setting for
Auto Restart. The dryer must be powered on for this
feature to take effect. To enable this feature:
• Install N.O. remote switch
appropriate wiring diagram.
• Customer-supplied contact should be rated at 1A at 24V.
To operate dryer, close switch or contact and allow dryer
to start after an initial delay.
pushbuttons may also be used at any time after contact
closure.
8.5

INITIAL START-UP

A
NOTICE
For water cooled models, the water valve must be manually opened to
A
ensure that the condenser is full of water prior to start-up.
CAUTION
Allow 8 hours of warm-up time for the crankcase heater prior to start
up. Crankcase heater is connected directly to the incoming power and
is energized at all times.
8.5.1

START- UP SEQUENCE

• Apply power to dryer. LCD Panel will illuminate. The Anti-
Short Cycle delay will commence counting down.
Remaining time on the Crankcase heater will also
countdown.
ingersollrandproducts.com
AIR OUT
DRAIN
OIL
VALVE
SEPARATOR
VALVE
as indicated on the
The local On / OFF