GAS CONNECTIONS (Cont.)
I. Place the oven in the cutout.
J. Level the oven:
1. Place a spirit level on one of the oven racks.
2. If the oven is not level, adjust the leg levelers.
3. Remove regulator cover at the back of the storage
drawer area by removing 4 screws.
With the oven in place, the pressure regulator inlet is
accessible through the opening in the main back.
K. Through this opening connect:
1.
or
2. The rigid pipe connection and union to the shutoff
Pressure Regulator
with Built-In Shut-Off
Valve
FLEXIBLE HOOK-UP
Pressure
Regulator
L. Tighten the fitting.
WARNING
DO NOT FORCE! FORCING COULD
DAMAGE THE FITTING, TUBING OR CAUSE
LEAKING.
31-2000792 Rev. 0
Installation Instructions
Regulator
Cover Plate
Adaptor
Flexible
Connection
Fig. 7
Regulator
Cover
Plate
Union
RIGID HOOK-UP
Fig. 8
6

CHECK FOR LEAKS

WARNING
DO NOT USE OPEN FLAME TO
CHECK FOR LEAKS!
A. Apply a soap solution to all connections: supply line,
manifold and oven.
B. Turn on the main gas supply.
C. Check for any bubbles to form.
D. Turn off main gas supply.
E. Stop any leaks found.
F. Turn main gas supply on to make sure all leaks were
stopped.
G. Replace the regulator cover using the 4 screws
previously removed.
WARNING
ALL LEAKS MUST BE STOPPED
BEFORE ATTEMPTING TO LIGHT BURNERS.
7
PRESSURE TEST INFORMATION
A. The maximum allowable pressure for the regulator is
B. The minimum pressure needed to check the
for Natural.
CAUTION
The range and its individual shutoff
valve must be disconnected from the gas supply
piping system during any pressure testing of the
gas supply system at test pressures in excess of
1/2 psig (pound per square inch gauge).
The range must be isolated from the gas supply piping
system by closing its individual manual shut-off valve
during any pressure testing of the gas supply system at
test pressures equal to or less than 1/2 psig.